6.1 Wiring diagram
(1) Lamp connection (load)
(2) Mains voltage connection
6.2 Installation
When mounting the twilight switch, ensure its sensor is not exposed to the lamp

light.
Never install the twilight switch under a lamp.

Ensure there are no moving objects in front of the twilight switch.

Nothing in front of the twilight switch should obstruct the exposure to natural

light.
1. Loosen the screws securing the cover and remove the cover.
2. Connect the cable to the product as shown in the wiring diagram.
3. Mount the product in the appropriate location using the screws provided.
4. Turn on the power supply.
5. Check the settings and adjust them as needed.
6. Replace the cover.
7 Operation
7.1 Switching threshold "LUX"
Use this dial knob to adjust the switching threshold for triggering the twilight switch for different
ambient light levels.
Dial settings:

– (+): increase the switching threshold
– (-):
decrease the switching threshold
7.2 Function test
To optimise settings or check the proper operation of the motion sensor, proceed as follows:
Set the "LUX" dial knob to "-" and turn on the power supply. When the ambient light is less

than 5 LUX (e.g. cover by hand or with a cloth), the lamp turns on.
When you remove your hand or cloth, the lamp turns off automatically..

8 Troubleshooting
Problem
Remedy
Connected load
Check the LUX setting; it should correspond to ambient light levels.
For example, if it is set too high, the sensor will not trigger in the dark.
does not switch on.
Check the power supply is functioning correctly.

Check if the connected load (e.g. lamp) is functioning correctly.

Check the electrical wiring.

The connected load
Check the LUX setting; it should correspond to ambient light

levels.
is always ON.
Check the electrical wiring.

The twilight switch
Check if the twilight switch is exposed to the lamp light.

constantly switches
The light emitted by the lamp affects the twilight switch. Move the

the load on and off.
lamp farther away from the twilight switch.
9 Cleaning and care
Important:
The product is generally maintenance-free. Any repair or maintenance work must be carried
out by a specialist.
– Wipe the product with a dry, fibre-free cloth.
– NOTICE! Do not use any aggressive cleaning agents, rubbing alcohol or other chemi-
cal solutions, as they can cause damage to the housing or cause the product to mal-
function.
10 Disposal
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should not be disposed of as
unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
in our Conrad offices

at the Conrad collection points

at the collection points of public waste management authorities or the collection points set

up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
11 Technical data
Operating voltage ......................... 220 – 240 V/AC, 50/60 Hz
Rated load .................................... max. 2000 W resistive (e.g. incandescent lamp)
......................................................
max. 500 W inductive (e.g. energy-saving lamp or LED)
Power consumption ...................... 0.5 W
Switching contact .......................... relay (NO contact); max. rated current 15 A
Twilight threshold .......................... < 5 – 50 lux (adjustable)
Protection rating ........................... IP66
Operating/storage conditions ........ -20 °C to 50 °C; < 93% RH
Dimensions (Ø x H) ...................... approx. 78 x 93 mm
Weight .......................................... approx. 120 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in elec-
tronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright 2024 by Conrad Electronic SE.
*2918272_V2_0224_02_m_VTP_en

Werbung

loading