Error codes
Display
38
| integral 2GO HsM
No.
Error/Service
F100
Error Pump
Pump does not turn
during dispensing
F200
Error Water
No water flow during
dispensing
F201
Min. water flow rate
F202
Max. water flow rate
F300
Error Refill
Bottle inserted incor-
rectly
F301
Error RFID
Data Version
F302
Error distributor
protection
F303
Error Product type
F304
Error RFID
Communication
S100
Service Pump
Pump life cycle
reached
S300
Service Refill
Refill empty
S301
Service Refill
Maximum quantity re-
moved from refill,
Refill empty
Remedy
Check pump head, replace pump
head as needed
Check water supply,
Open water supply
Water flow rate too low
Water flow rate too high
Reduce water flow through
pressure regulator
Unlock refill, push bottle down
and lock
Wrong product
Wrong product,
wrong distributor protection
Wrong cartridge,
Wrong Market encoding
Exchange PUMP integral 2GO
(See "Pump exchange" with
instructions)
Unlock, remove the empty refill
and insert new refill
Unlock, remove the empty refill
and insert new refill