Herunterladen Diese Seite drucken

EBRO ARMATUREN Berluto SP90 Betriebsanleitung Seite 14

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Maintenance
Overflow valves are sensitive to dirt. Contamination or foreign bodies inside can lead to functional
restrictions or even a functional failure. We therefore recommend installing an additional filter in the inlet
pressure area of the overflow valve to keep dirt away from it.
The automatic function of the valve requires maintenance for proper operation. It is important that
maintenance work is planned and carried out at periodic intervals.
Depending on the nature of the flow medium, overflow valves may require annual maintenance.
When operating in limit ranges, the maintenance interval may be further reduced.
Model plan maintenance intervals
maintenance type
functional test
Check tightness of the housing, the
pipeline connection.
Clean dirt trap
(If installed in front of the fitting)
Preventive maintenance
The time intervals listed here are recommendations and guide values. They may vary depending on
1)
the prevailing operating conditions, the properties of the medium and the user's experience.
Berluto Armaturen GmbH accepts no liability for damage resulting from improper maintenance and/
2)
or repair.
Repair kits can be requested from Berluto Armaturen GmbH.
3)
When restarting a previously disassembled valve, check the tightness and function of the valve as
4)
well as the correct adjustment of the control and functional components.
In rare cases, the diaphragm may be damaged, for example by foreign bodies, by excess temperature or
by aggressive media.
In such cases, a leak to the outside occurs. This is immediately recognizable because the medium then
flows through the vent hole in the spring cap.
Overflows should therefore be inspected regularly (see table) so that such damage can be detected at an
early stage.
work steps to be performed
Check whether the function of
the valve is achieved according to
requirements.
Visual inspection
Act only according to the manufactur-
er's instructions.
Disassemble the valve according to the
manufacturer's instructions.
Visual inspection of the internal parts.
Replace all parts of the repair kit.
periode
At least 1x per week
(at each commis-
sioning)
At least 1x per week
(at each commis-
sioning)
According to manu-
facturer's instructions
(strongly media-de-
pendent)
At least. 1x per year
2)
3) 4)
1)

Werbung