Operation:
To vacuum liquids it´s necessary to remove both filters (G) (H).
The filters (G) (H) needs to be installed if you intend to vacuum dust and objects to
prevent damages on the motor.
Connect the hose assembly to the intake fitting, the power cord to the electrical socket
and switch on the unit.
The tool is equipped with a float lever which will stop the motor in liquid suction mode if
the tank is full. Disconnect the power cord and open the unit to drain the tank.
In dry mode you can optional use paper- or polyester bags to collect the dust and
objects. Ask your dealer for the related original accessories.
Cleaning:
Disconnect the power cord and open the unit.
Wash out the filter (G) (H) with water and a soft cleaning agent frequently.
Make sure the filters are dry before reinstall them.
A polluted sponge filter needs to be cleaned or replaced. You need to unscrew the filter
cage for replacement.
If you recognize a damage on one of the filter (E) (G) (H) you need to replace them
immediately.
Drain the tank as soon as possible.

Troubleshooting

Problem
No function
Unit switched off automatically
Unit switched off automatically
Decreasing suction power
Decreasing suction power
Possible reason
Power supply
Float lever
Thermo switch
Full tank or full optional bag
Filter or hose blocked.
15
Correction
Check power supply. (Fuse, circuit
breaker, switches, cable, power
outlet)
Disconnect the power cord, open
the unit and drain the tank.
Cool down the unit for a while.
Switch off and on again
Disconnect the power cord, open
the unit and clean the tank or
replace the bag.
Check and remove blocking.