Casanoov BUNKER B500 Bedienungsanleitung Seite 28

Vorschau ausblenden Andere Handbücher für BUNKER B500:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 61
EN
5b. When the digital display shows P8, the actuator is in close interval time setting mode.
Options range from 0 to 10s. (default 0s)
00: Both leaves close simultaneously.
00 - 10: Motor 2 starts to close 0-10 seconds before motor 1 starts to close.
6.To set the automatic closing delay :
When the digital display shows P9, the actuator is in auto close delay setting mode.
Options range from 0 to 99s (default 0s)
00: The gate will not close automatically.
7.To set lamp/alarm output control:
When the digital display shows PA, the actuator is in «lamp/alarm» setting mode. Options range from
0 to 3 (default 0)
00: Alarm on monostable / flashing beacon model flashes 30s after end of open/close cycle.
01: Alarm on monostable model / flashing beacon flashes only when gate is moving.
02: Alarm on bistable model / flashing beacon flashes 30s after the end of the opening/closing cycle.
03: Alarm on bistable model / flashing beacon flashes only when gate is moving.
8.To set the locking time :
When the digital display shows Pb, the operator is in lock time setting mode.
Options range from 0 to 1.
00: Lockout control time is 0.5s
01: Lockout control time is 5s.
9.To select single or double leaf opening:
When the digital display shows PC, the operator is in opening setting mode (default 3)
00: The gate cannot be opened remotely
01: Gate opens in pedestrian mode only
02: The gate opens only when fully open
03: Gate can open in pedestrian or full opening mode
10.To select NC or NO operation of the photocell
When the digital display shows Pd, you can select whether the photocell is to operate in NO or NC mode.
00: NO.
01: NC.
11.To reset :
When the digital display indicates Po, press the [FUN] button to memorise, then re-initialise successfully.