INSTALLATIoN
Safety
INSTALLATIoN
4.
Safety
Only qualified contractors should carry out installation, commis-
sioning, maintenance and repair of the product.
4.1
General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the product
are used.
Material losses
If the high limit safety cut-out of the DHW cylinder has
responded, replace the flexible hoses of the safety as-
sembly before recommissioning.
4.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
5.
Product description
You can retrofit a pressure reducing valve.
5.1
Standard delivery
The following are delivered with the product:
- Safety valve with drip facility
- Shut-off valve with pressure gauge connection
- Tundish with pipe collar
- Flexible hose cold water connection with union nuts, 250 mm
long
- Flexible hose DHW connection with male thread and union
nut, 250 mm long
- Flat gaskets
6.
Installation
6.1
Product installation
Note
For installation, observe the DHW cylinder operating and
installation instructions.
The safety assemblies are suitable for installation on finished
walls.
f Before installing the safety assembly, compare the maximum
permissible pressure of the DHW cylinder with the response
pressure of the safety valve.
www.stiebel-eltron.com
7
6
5
4
1 Flexible hose cold water connection
2 Cold water inlet
3 Shut-off valve with pressure gauge connection
4 Tundish with pipe collar
5 Safety valve with drip facility
6 Locking clip
7 Flexible hose DHW connection
Note
Ensure that the flexible hoses are not kinked, turned or
interchanged during installation. Prevent any tensioning
during installation.
f Flush all water pipes thoroughly before installation.
f The safety valve discharge aperture must remain open to the
atmosphere.
f Seal in the male thread of the flexible hose. Screw the flexi-
ble hose into the wall connection for DHW.
f Connect the flexible hose including flat gasket to the DHW
connection of the DHW cylinder.
f Seal in the safety assembly. Screw the safety assembly into
the wall connection for cold water.
f Connect the safety assembly and the cold water connection of
the DHW cylinder to the flexible hose including flat gaskets.
f Tighten the fittings.
f Fit the tundish with the pipe collar to the drain pipe.