(cont.)
PROBLEM
The Learn indicator light comes
on for 5 seconds.
The Learn indicator light comes
on for 10 seconds.
The Learn indicator light no longer
blinks during learning.
During learning, pressing the
programmed control button does not
make the Learn indicator light
blink rapidly.
When the scenario is saved the Learn
indicator lights of certain receivers do
not go out.
CAUSE
Learning is impossible.
The number of transmitters memorised
is greater than 32.
The learning mode closes after 10
minutes (if no action is taken).
After a press on the Learn key,
Function key learning must be done
within the following minute.
Poor communication between products. Reduce the distance between the
12
SOLUTION
Install compatible products.
Delete unused scenarios.
Start learning again.
Start learning again.
transmitter and the receiver(s), then
start learning again or add a repeater.