4. How to use
1. Fill water tank to the "MAX" mark; water
will flow through the filter at a set rate and
may take some time due to the action of
the filter cartridge.
2. Adjust the height of the drip tray to
accommodate the size of the mug used.
To reposition the drip tray use two hands
to lift it vertically before removing from
the unit. Keep the drip tray horizontal,
rotation or twisting may damage the
hooks that connect the drip tray to the
appliance. Ensure the drip tray is fully
engaged with the appliance. There are 3
height options (A).
3. Place mug or glass on drip tray (B).
4. Press the On/Off button. The On/Off
button will light up blue (C).
5. Press the desired volume setting (D).
6. Press the dispense button to start
dispensing. One beep at the start (E).
7. The dispense button will fade in and out
whilst dispensing and beep twice once
complete.
Note:
• To stop the cycle at any time press the dispense button.
Once the cycle has stopped it cannot be continued. A
new cycle must be started.
• Sound – all remaining buttons can be turned off (not
sound in 6. & 7.) in How to use guide, section 4.) by
pressing and holding the 200ml and 1000ml buttons for
3 seconds.
• The chilled icon
will light up blue when the water
in the appliance is chilled and turn off when the water
is being chilled. At first use the chiller takes around 40
minutes to fully cool down the water (can vary depending
on the incoming water temperature and ambient room
temperature).
• The refill icon will turn orange when the water tank needs
refilling or if the tank is not fitted correctly.
• The filter icon will turn orange when the filter needs
replacing, at 100L usage, follow the filter preparation and
replacement instructions in this manual.
TROUBLESHOOTING
Condition
Machine will not start.
Refill water warning symbol on
screen.
Change filter warning symbol on
screen (will illuminate after 100L).
A
B
C
D
E
Possible cause
Appliance is unplugged.
Water tank is empty.
Tank may not be fitted
correctly.
Filter life expired.
4
5. Installation
The appliance comes with two plug types, one for UK and
one for EU, the correct plug should be used and inserted
into the plug socket.
WARNING: PLEASE DO NOT DISASSEMBLE THIS
APPLIANCE YOURSELF. ELECTRIC ELEMENTS WILL BE
EXPOSED AND THERE IS A RISK OF ELECTROCUTION
POSITIONING OF APPLIANCE
• Do not install this appliance in a very damp or hot place
or near heat source.
• Place the appliance on a flat and even surface.
• Install the appliance in a dry place to avoid damage,
moisture or rust.
• Do not use this appliance outdoors. This appliance is
only suitable for use indoors.
• Do not overhang the power cord and/or water tray off a
table, counter or other surface and avoid contact with
hot surfaces.
• WARNING: DO NOT INSTALL THIS APPLIANCE IN
DIRECT SUNLIGHT.
• Ensure that the ventilation on both sides is never blocked
or covered and ensure a minimum distance >4 inches
(100mm) from the rear wall and right side as shown in the
image.
• WARNING: When positioning the appliance, ensure the
supply cord is not trapped or damaged.
• WARNING: Do not locate multiple portable socket-outlets
or portable power supplies at the rear of the appliance.
Solution
Ensure the power cord is inserted in the appliance
and the plug is securely placed into the socket.
Refill water tank to above minimum level.
Reassemble the water tank, making sure that the top of
the tank is flush with the top of the machine.
Change filter following the Aqua Optima filter
instructions. Reset filter warning symbol by holding for
3 seconds.