Slow CO2 cal
>> HOME <<
Turn the PTK and select "Slow CO2 cal".
=> Slow CO2 cal
>> HOME <<
Press the PTK once to enter the calibration menu.
CO2 calibration
Push to continue
If you do not do anything, the T-Mini will return to the
main menu after a few seconds.
Press the PTK, to enter the next screen:
Place sensor outside
Push to continue
If you do not do anything, the T-Mini will return to the
main menu after a few seconds.
Place the T-Mini in a suitable environment. Press the
PTK, to enter the next screen:
Hold button ...
----------------
outside
Push to continue
If you do not do anything, the T-Mini will return to the
main menu after a few seconds.
Press and hold the PTK to start calibration. The dashes
change one by one into asterisks, The T-Mini counts
down for 12 hours, after which calibration is started.
After completing calibration, the next screen is
displayed:
Done!
Push to end
Press the PTK once to return to the main screen.
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
8. Replace the fuse
If the T-Mini is overloaded or in the event of a short
circuit, the internal fuse will break. To replace the fuse
you have to open the T-Mini. Go through the following
steps:
1. Remove the plug from the socket.
2. Open the housing by unscrewing the 4 screws on
the back of the T-Mini.
3. Locate the fuse and remove it.
4. Insert a new 4 amp fuse.
5. Screw the 4 screws to close the housing.
6. Your T-Mini is ready for use again.
9. Reset to factory settings
1. Disconnect the power supply to the T-Mini.
2. Press and hold the PTK and plug the T-Mini into
the wall socket (keep the PTK pressed for a while).
3. The type and software version of the controller are
displayed on the screen.
4. Then, you will enter the main menu, including the
next options:
Fact. default
Hardware test
Light detect
Quick CO2 cal
Slow CO2 cal
>> HOME <<
Turn the PTK and select "Fact. default".
=> Fact. default
Hardware test
Press the PTK.
Resetting ...
The T-Mini is reset to factory settings within a few
seconds. You automatically return to the main menu.
To return to the main screen, select >> HOME << and
press the PTK.