Herunterladen Diese Seite drucken

IFM Electronic efector500 PF79 Bedienungsanleitung Seite 25

Elektronischer drucksensor

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. Installation and set-up / operation
After mounting, wiring and setting check whether the unit operates
correctly.
Faults displayed during operation:
= overload pressure
(as from approx. 110% of the max. nominal pressure)
(flashing) = short-circuit in switching output 1/ 2;
the respective output is switched off
Cleaning of the filter cover
If viscous and residues producing
media clog the filter cover of the
sensor (and thus reduce the mea-
suring accuracy slightly), you can
clean it.
Unscrew the filter cover (B) (use a
pair of pliers with plastic-covered
jaws for this). Clean the cover
thoroughly.
The vent (A) should only be clea-
ned by skilled personnel and
with utmost care.
Possible medium residues must not be compressed and pressed
into the vent. This could clog the filter system and reduce the
measuring accuracy of the sensor.
Screw the filter cover again tightly.
The sensor is sufficiently protected against harsh ambient conditions
(protection IP 67). The protection rating can be increased by a special
accessory (order no. E30043).
A B
25

Werbung

loading