Herunterladen Diese Seite drucken

IFM Electronic efector500 PF79 Bedienungsanleitung Seite 17

Elektronischer drucksensor

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. Function and features
• The pressure sensor detects the system pressure,
• shows the current system pressure on its display (indication as
from 1% to 105% of the value of the measuring range)
• and generates 2 output signals according to the set output
configuration.
Switching function
(can be selected for each
output separately)
The unit is EHEDG 3A certified
Applications:
Order no.
PF79x3
PF79x4
PF79x6
PF79x7
PF79x8
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
Indication of the current system pressure as from 1% of the
value of the measuring range. Display "0" does not mean that
the system is free of pressure!
Measuring range
0 ... 25 bar
0 ... 10 bar
0 ... 2.5 bar
0 ... 1 bar
0 ... 250 mbar
output 1
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
Permissible
overl. pressure
100 bar
50 bar
20 bar
10 bar
10 bar
output 2
Bursting
pressure
200 bar
150 bar
50 bar
30 bar
30 bar
17

Werbung

loading