Herunterladen Diese Seite drucken

axing TVS 10-00 Betriebsanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Field of application:
The devices are suited only for distributing radio and television signals in the
house! If the device is used for other purposes, no warranty is given!
The illustrations show application examples of the distribution in star (1) or
tree structure (2).
Equipotential bonding and Mounting:
To avoid dangerous overvoltages (attention: risk of fire/death), the devices
must be connected to the equipotential bonding according to EN 60728-11.
 Use the equipotential bonding connection attached to the device (3).
 To connect the outer conductor of the coaxial cable to the equipotential
bonding, use e.g. earth connection blocks CFA 7-01 at the input and output
of the amplifier.
 Use the mounting screws included in the delivery and the mounting holes
of the devices (4).
4
5
Level Adjustment:
The input level may be adjusted with the attenuator (5).
Page 2 of 2 | BA_TVS-10-00 | 2021-08-19
Coax
Equipotential bonding
3
1
BVE 6-02P
QEW 6-50
RF Installation:
 Connect the input of the TVS 10-00 to the video interconnection point.
BSD 4-18N
2
 Use highly shielded coaxial cables with F/IEC connectors. Suited cables
BSD 4-14N
BSD 4-10N
CFA 7-01
CFA 7-01
Connect the output of the amplifier to the antenna sockets or the taps/
splitters used.
and plugs can be found at www.axing.com.
IP

Werbung

loading