3.
Use UP and DOWN buttons to select group number.
4.
The group number is flashing on the display until it has connected to the
network of Spirocom units.
5.
When connected the UP and DOWN buttons are disabled. To change
group number the Spirocom generic radio adapter must be switched off.
6.
Switch off the unit by pressing the ON/OFF button until "--" is shown on the
display and then release the button.

Battery replacement

1.
Open the cover on the backside with a Pz 1 screwdriver.
2.
Insert two new batteries according to the markings in the battery
compartment.
3.
Place the strap over the batteries and insert the third battery according to
the marking in the battery compartment.
4.
Put on the battery cover and tighten the screws moderately.
The unit will start automatically after a few seconds.
IMPORTANT
Always use the specified AAA alkaline batteries "Duracell
MN2400" or "Energizer E92". Interspiro assumes no liability for
mechanical, electrical or any other type of battery failure.
IMPORTANT
Do not mix batteries of different manufacturers or old batteries
with new batteries.
IMPORTANT
Cold conditions during storage and use will decrease battery
life.