FOR SLIDING GATE AUTOMATIC SYSTEMS WITH LIMIT SWITCHES:
dip-switch - B n° 1 = ON
Dip-switch A
1 = ON Photocells stop gate in opening
2 = ON Radio, no reversing in opening
3 = ON Automatic closing
4 = ON Pre-flashing in service
5 = ON Radio step-by-step
6 = ON Traffic lights mode limit switches connected
Dip-switch B
1 = ON SLIDING GATE mode
2 = ON Hold-on-switched control mode (deadman control)
3 = ON Traffic lights on "yellow" for 3 seconds
4 = ON DSA control by photocell transmitters if connected to the dedicated terminals
ELECTRICAL CONNECTIONS ON SLIDING GATE MODE - dip-switch - B n° 1 = ON
Accessory
nd
2
pair photocells
(fitted inside perimeter):
st
1
pair photocells
(fitted outside perimeter):
Key-switch:
Radio contact
(step by step mode):
Indication lamp output
24 V max 3 W:
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230 V - 50/60 Hz
7 = OFF: blank
8 = OFF: blank
nd
9 = ON 2
10 = ON Flasher off in dwell time
11 = ON Gate re-closing in opening and dwell on photocells engaging
12 = OFF: blank
Electrical connections
This pair of photocells stops gate in opening;
once cleared from obstacle, gate goes on
opening, gate travel is reversed in closing.
NC
Dip-A n° 9 = ON and the NC contact connected: the gates
stay stopped as long as the photocells are obstructed.
- In opening cycle: obstacle removed, gates go on opening
- In closing cycle: obstacle removed, gate travel reversed
nd
NOTE: if no 2
pair photocells are used, it is not
necessary to bridge the contact input, only dip-A
n° 9 = OFF
1
2
NC
NC
All of the NC contacts of the safety
accessories such as the photocells
(receivers)
are
to
connected to terminals 1 and 2
NO and NC contacts to be connected
3
4 5 6
to the respective terminals in the key-
or
button-switches.
possible setting combinations are
described in the instructions sheets
NC
included with the respective control
accessories
Any NO connection to these two terminals
3
7
will perform the following:
- Opening only: dip 2 = ON and dip 5 = OFF
- Gate travel reversing by any pulse
dip 2 = OFF and dip 5 = OFF
- Step by step: open-stop-close-stop
dip 2 = OFF and dip 5 = ON
- No new pulse is accepted in opening.
In Dwell phase and in closing any new
RADIO
pulse stops and reverses gate travel:
CONTACT
dip 2 = ON and dip 5 = ON
Output for a 24 V max 3 W indication lamp showing the status of the system:
3
11
Lamp ON = gate open
Lamp OFF = gate closed
0,5 s (fast) flashing = gate closing
1 s (normal) flashing = gate opening
pair photocells in service
12 13
24 Vac output max load:
n° 1 radio receiver
n° 3 pairs photocells
be
series
All
of
the
16
DIP-SWITCH - B
ON
OFF
1
2 3 4
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - B
ON
OFF
1 2 3 4
Dip-Switch setting and LED indication of functions
DIP-SWITCH - A N° 9:
nd
ON: Photocells 2
pair in service
9
nd
OFF: Photocells 2
pair not installed
L0 ON = no obstacle detected,
it goes off in case of obstacle
DIP-SWITCH - A N° 1:
ON: gate is stopped in opening and reversed
in closing once cleared from obstacle
OFF: gate is not stopped in opening and is
1
reversed in closing in case of obstacle
L1 ON = no obstacle detected,
it goes off in case of obstacle
L4 OFF = no OPENING contact,
it goes on whenever an opening pulse is given
L5 OFF = no CLOSING contact,
it goes on whenever a closing pulse is given
L6 ON = STOP contact closed,
it goes off whenever a stop pulse is given
DIP-SWITCH - A N° 2 and N° 5:
ON: it does not stop and reverse gate travel
in opening
2
OFF: always stops & reverses in opening
ON: step by step with intermediate stop
5
OFF: gate travel reversed by any radio pulse
L7 OFF = no RADIO contact,
it goes on by any radio pulse
DIP-SWITCH - A