2 PRODUCT DESCRIPTION
Models and contents of the package
The name GHOST 200 identifi es a series of underground electro-mechanical operators for the automation of swing gates with diffe-
rent features depending on motor phase power supply and the presence of the encoder.
GHOST 200 is completed by a set of accessories listed in the "PRODUCT ACCESSORIES" table (page 70).
GHOST 200 is an electromechanical operator for swing gates rotating an articulated arm. This arm is connected to the gate to be
operated by means of the lever unit of the foundation box. The lever unit, that will be properly welded at the time of installation, has a
built-in operator unlocking device which will allow you to open the gate even if there is a power supply failure.
Inspect the "Contents of the Package" (Pic. 1) and compare it with your product for useful consultation during assembly.
Transport
GHOST 200 is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all infor-
mation that may be provided on the same box for storage and handling.
3 TECHNICAL DATA
Motor power supply voltage (V)
Absorbed power (W)
Max torque (Nm)
Duty cycle (cycles/hour)
Maximum n° of operations in 24 hour *
Built-in capacitor (μF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening time 90° (s) *
Maximum opening degree
Weight of product with package (kg)
Sound pressure emitted (dBA)
Protection degree
* The data refer to the use in combination with NET series control boards and with parameters of speed and slowdown set as per
default.
4 INSTALLATION AND ASSEMBLY
4.1 For a satisfactory installation of the product is important to:
• Verify that the structure complies with the regulations and then defi ne the complete design of the installation;
• Make sure the gate is well balanced and there aren't points of friction while closing and opening;
• Identify an area that allows a smooth and safe manual operation of the operator;
• Ensure that the foundation box dimensions are conformable with the selected area for the assembly (Pic. 2);
• Provide a stop stroke in closing and possible also in opening;
• Use the lenght/weight diagram and installation dimensions provided (Pic. 4) for a correct positioning of the box with respect to the
door to be moved.
200 - 200CL
200/EN - 200/CLEN
230-240 V ~ (50/60 Hz)
400
320
20 - 28
(200/EN & 200/CLEN)
200
12,5
150 °C
17
14,5
200L - 200L/CL
200/24 - 200/24CL
330
300
18
-20 ÷ 50 °C
26
107°
< 70
IP67
GHOST 200
24 V
150
210
40
280
/
/
16
14