Herunterladen Diese Seite drucken

BabyOno HTD8813 Montageanleitung Seite 11

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
Guidance and manufacturer's declaration - RF wireless communication equipment immunity
test
Band
frequency
(MHz)
(MHz)
385
380 - 390
450
430 - 470
710
704 - 787
745
780
810
870
800 - 960
930
1720
1700 -
1845
1990
1970
2400-
2450
2570
5240
5100-
5500
5800
5785
a) For some services, only the uplink frequencies are included.
b) The carrier shall be modulated using a 50 % duty cycle square wave signal.
c) As an alternative to FM modulation, 50 % pulse modulation at 18 Hz may be used because while it does not reoresebt actual
modulation, it would be worst case
Body temperature
1) Body temperature varies from person to person and fluctuates during the course of the day. For this reason, it is suggested to know one's
normal, healthy forehead temperature to correctly determine the temperature.
2) Body temperature runs approximately from 35.5°C to 37.8°C (95.9°F-100°F). To determine if one has a fever, compare the temperature
detected with the person's normal temperature. A rise over the reference body temperature of 1°C (1°F) or more is generally indication
of fever.
3) Different measurement sites (rectal, axillary, oral, frontal, auricular) will give different readings. Therefore it is wrong to compare the
measurement taken from different sites.
4) Here below are typical temepratures for adults, based on different measurement sites:
- Rectal: 36.6°C to 38°C/97.9°F-100.4°F
- Axillary: 34.7°C to 37.3°C/94.5°F-99.1°F
ASTM laboratory accuracy requrements in the display range of 37°C to 38.9°C (98°F to 102°F) for IR thermometers is ±0.2°C (±0.4°F),
whereas for mercury in-glass and electronic thermometers, the requrement per ASTM Standards E667-86 and E1112-86 is ±0.1°C (±0.2°F).
Caution: This infrared thermometer meets requirements established in ASTM Standard (E1965-98) Except of clause 5.2.2. It displays subject's
temperature over a range of 34.0~43,0°C. Full responsibility for the conformance of this product to the standard is assumed by Hetaida
Technology Co., Ltd Adds: Room 801, 802, 803, 804, 901, 2# Building Scientific Research Center; Songhu Intelligent Valley, No.6 Minfu Road,
Liaobu Town, Dongguan City, Guangdong Province, P.R.China.
Service
Modulation
TETRA 400
modulation
GMRS 460,
±5 kHz deviation
FRS 460
1 kHz sine
Pulse modulation
LTE Band 13,
17
GSM 800/900,
Pulse modulation
TETRA 800,
iDEN 820,
CDMA 250,
LTE Band 5
GSM 1800;
CDMA 1900;
Pulse modulation
GSM 1900;
DECT;
LTE Band 1, 3,
4, 25; UMTS
Bluetooth,
Pulse modulation
WLAN,
802, 11 b/g/n,
RFID 2450,
LTE Band 7
Pulse modulation
WLAN 802.11 a/n
Maxiumum
power
(W)
Pulce
1,8
18 Hz
FM
2
0,2
217 Hz
2
18 Hz
2
217 Hz
2
217 Hz
0,2
217 Hz
IMMUNITY
Distance
test level
(m)
(V/m)
0,3
27
0,3
28
0,3
9
0,3
28
0,3
28
0,3
28
9
0,3
11

Werbung

loading

Verwandte Produkte für BabyOno HTD8813