AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
Power Linking
You can link up to 7 onAir IP Panel 1 products at 100 V, 8 products at 120 V, 15 products at 208 V, 16 products at
230 V, or 17 products at 240 V. Never exceed this number. Power linking cords can be purchased separately.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
DC Power
This product has a 3-pin IP65 XLR power input port that can work with an input voltage of 28 V DC which is SELV voltage
supplied by short-circuit-proof power supply.
If AC power and DC power are input to the product at the same time, the product will automatically
give priority to AC power input.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
Signal Connections
The onAir IP Panel 1 will work with a controller or controller software using a wired DMX connection, a wireless
Lumenradio CRMX™ connection, or an Ethernet connection, If using other Art-Net™ or sACN-compatible products with
the onAir IP Panel 1, each can be controlled individually on a single network. See the User Manual for information about
how to connect and configure the product for these signals.
Control Personalities
uses
The onAir IP Panel 1
6Ch
8Ch1
8Ch2
10Ch
,
,
,
DMX Connection
The onAir IP Panel 1 will work with a DMX controller using a 5-pin DMX data connection or a wireless CRMX™
connection. A DMX Primer is available from www.chauvetprofessional.com.
Art-Net™ Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik®
etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from
www.chauvetprofessional.com. Chauvet Professional recommends using unicast Art-Net™ for best results.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller's User Manual or with the manufacturer as not all DMX controllers
have this capability. The onAir IP Panel 1 supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from
USB Software Update
The onAir IP Panel 1 allows for software update through USB using the built-in USB port. To update the software using
USB flash drive, do the following:
1. Power on the fixture and plug the flash drive into the USB port.
2. Once the flash drive has been detected, the message "Upgrade Firmware" will be displayed. Press <ENTER>.
If a different message appears on the display, search for the updated software in the Main Menu (Update
Firmware) and select from Only This Unit, Multiple Units, or Other Fixture Type. A list of the software
update files will be displayed.
3. Select the file that needs to be uploaded. The message "Are you sure?" will be displayed. Press <ENTER>.
4. If the selected file is correct, the upgrade will be completed. Restart the fixture.
If the selected file is incorrect, the upgrade will fail, and the display will go back to the main interface. Repeat
steps 1-3 using the correct file.
The .chl format file needs to be placed in the ONAIR folder in the USB flash drive.
The "Other Fixture Type" option can only be selected for connected products compatible with the
Upload 03 (the first 2 digits of the item code must be 03).
onAir IP Panel 1 QRG Rev. 7
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
DMX, CRMX™, Art-Net™, and sACN for its control personalities:
11Ch
15Ch1
15Ch2
,
,
,
www.chauvetprofessional.com
Wire (Europe)
Brown
Blue
Green/Yellow
16Ch
,
, XYBasic(6), and XYExtended(10).
for more details.
EN
Screw Color
Yellow/Brass
Silver
Green
1Ch
3Ch
4Ch
5Ch
,
,
,
,
2