PLACEMENT
The device must be instalated in well ventilated room what is necessary for regulation of the function of the
device (technician must go by valid standard (EN....). If the device is situated close to the wall or if it is in
contact with the furniture walls, these walls must resist the temperatures ranging to 90°C. Instalation, setting,
putting into operation must be done by qualifi ed person who is competent for this and according to the valid
standards.
Wrap up the device and check whether it was not damaged during transport. Settle the device on horizontal
surface (max imbalance 2°).Settle the device under the fumehood to eliminate water steam and bad smell.
The device can be instalated separately or in a set with devices of our production. Min. distance 10 cm
from other subjects must be kept.It is also necessary to prevent our product from contact with combustible
materials. In this case you must make corresponding changes to secure heat izolation of combustible parts.
Safety measures from the standpoint of the fi re protection according to EN 061008čl. 21:
TECHNICAL INSTRUCTIONS FOR INSTALATION AND REGULATION
Important:
The manufacturer does not provide warranty for defects caused by improper use, failure to instructions
contained in the attached instructions for use and mistreatment of the appliances.
Installation, adjustment and repair of appliances for kitchens, as well as their removal because of possible
damage to the gas can be carried out only under a maintenance contract, this contract may be signed with an
authorized dealer, and must be complied with regulations and technical standards and regulations regarding
the installation, power supply, gas connection and health & safety system.
These instructions are intended for the qualifi ed technician who must perform the installation, put it into
SAFETY
MEASURES
operation and test the appliance.
PROTECTION ACCORDING TO EN 061008 ČL. 21
Any activity as settings, placement, rebalancing etc, must be made only when is device disconnected from
• only adults can operate the device
electricity. If it is necessary to have the device connected to the electricity you must keep the highest attention
• device must be safely used in common surroundings according to EN 332000-4-462; EN 332000-4-42. You
to avoid any injuries.
must switch the gas device off under the circumstances leading: to the danger of the temporary rise of the
combustion gas or steam or during works when there is a big possibilityof rise ot the temporary fi re danger
DEVICE INSTALATION
or explosion (for example: to stick linoleum, PVC etc.).
• before you start to instal the device you must get the licence for connection to the gas feeder from the
Instalation, setting, rebuilding for another gas type, putting into operation must be done by qualifi ed person
gasworks
whois competent for this and according to the valid standards. The device can be instalated in good ventilated
• device must be placed so as to stand or hang on the noncombustible surface which is on each side 10
room. When it is possible place the device under the fumehood to suck off the products of combustion. Air
cm larger than the device. No subjects from combustible materials can be placed directly on the device
needy to the burning is 2m/3/h/kW ot the performance of the instaled device. The device can be instalated
or in distance which is shorter than safety distance (the shortestdistance is 50 cm in the direction of the
separately or in a set with devices of our production. Min. distance 10 cm from other subjects must be kept.It
heat emission and 10 cm in other directions).- safety distances from various materials of diff erent degree of
is also necessary to prevent our product from contact with combustible materials. In this case you must make
combustion and information about the degree of comb. of common building materials - see chart:
corresponding changes to secure heat izolation of combustible parts (for example:place between the device
and combustible material azbestos plate).
Chart:
Combustion degree of building materials classifi ed according to the combustion degree of materials and
products (EN 730823)
A noncombustible
B uneasily combustible
C1 hardly combustible
C2 middle combustible
C3 easily combustible
Devices must be instalated in a safe way. When instaling you must respect corresponding project, safety and
hygienic orders according to:
• EN 061008 fi re protection of local devices and sources of heat
33 2000-4-482; 33 2000-4-42)
4
• EN 332000 (
• Gas fi ttings in the buildings - the highest operational pressure < 5 bar - operation demands
• § 10 law nr. 185/2001 Sb. about waste
FROM
THE
granit, sandstone, concretes,bricks, ceramic wallfacing tiles, plaster
akumine, heraklite, lihnos, itavere
leafy wood, plywood, sirkoklit, rare paper formica
fi breboards, solodure, cork boards, rubber,fl oor-coverings
wood-fi breboards, polystyrene,polyurethane, PVC
surrounding for electric devices ČSN EN 1775 Gas supplying
STANDPOINT
OF
THE
FIRE

Werbung

loading

Diese Anleitung auch für:

Ft-30 md