Herunterladen Diese Seite drucken

Pfaff-silberblau SW W-SGG Betriebsanleitung Seite 12

Wandwinde

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Wall-Mounted Wire Rope Winch SW W-SGG
English
with enclosed worm gear pair
Operating failures and their causes
failure
In unloaded state, it is
Lubricant in bearing
difficult to turn the
points and gearing is
crank.
missing.
Winch was distorted
during mounting.
Load is not held
Load too light
Load is not held, crank
Wrong coiling of the
rotates in reverse
rope winding.
Direction for lifting was
not correct.
Load is not held,
Stopper blocked
stopper does not
Pressure spring defective
engage (no noise
during lifting)
1)
for example by Pfaff-silberblau service department.
Disposal
After placing out of service, the parts of the hand winch have to be recycled or
disposed according to legal regulations!
design changes under reserve
cause
Execute maintenance procedures
Check the fixing. Is the mounting surface even, are the screws
tightened correctly?
Make the load heavier (
Lay the rope correctly
Repair only by authorised expert
• Unscrew and remove locking screw (1)
• pull out of housing
• Check and if necessary replace release
spring and mushroom head rivet
• Check stopper (visible from upper side)
for free movement and release if
necessary by slightly striking against the
stopper
• Re-assembly by reverse order
Function check
F04.02.063
elimination
minimum load see technical data)
1)
page 12
1

Werbung

loading