Herunterladen Diese Seite drucken

Dual CD 1065 Serviceanleitung Seite 3

Vorschau ausblenden Andere Handbücher für CD 1065:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

,r
Tuning
instructions for
GD
1065/CD
1070
Proceed
as
follows to enter the test mode:
1,
PowerOFF
2.
Short-circuit test points P03 and P04.
3,
Power
ON and
remove
shon circuit.
4.
0
:
test mode appears
in
the disptay
5.
Press
the
play key
to set test mode
1
or
2.
6.
To
exit
test mode: power
OFF
Signal
source
Equipment setting
Connection of measuring
instrument
Item
to
be
tuned
lüning
remarks
PLL
Test
mode
0
1.
2.
Shorl-circuit
P 0B
to earth
Frequency
counter
to
PLCK
VR
101
4.321 MHz
+
10
kHz
Remove
shon circuil
Phillips
test disc
5A
EF
balance
Test
mode
1
Carefully
turn CD with
your finger
Oscilloscope
to
P
06
(rE)
VR 103
DCOVA=B
Focus balance
Test
mode
2
uscrlloscooe
to
P
{)/
VR
]02
Clear
EFI\,4
signal
ca,
1.3 VSS
Focus gain
Test
mode
2
1.
AF
voltmeter
to
P
09
2.
with tone generator
1.2 kHz 300
mV
via 10
kohms
toP05
VR
104
55
mV AC
Tracking gain
Test
mode
2
1
,
AF
voltmeter
to
P
10
2.
with tone generator
1.2 kHz 300 mV
via
1O
kOhms
toP06
VR
105
52
mV AC
Basic setting of controller
prior
to tuning
(only
when device
is
not operatlng)
VR
101
centre
VR
102
centre
VR
103
centre
VR
104
left
stop
VR
105
right stop
3

Werbung

loading

Diese Anleitung auch für:

Cd 1070 rc