Function and features
• The pressure sensor detects the system pressure,
• shows the current system pressure on its display,
• and generates 2 output signals according to the set output
configuration.
Analogue output
(only output 2)
Switching function
(output 1 and output 2;
function can be selected for
each output separately)
Output polarity (applies to both
switching outputs)
Display range
mbar
inH
O
2
kPa
Applications
Type of pressure: relative pressure
Measuring range
mbar
inH
O
2
kPa
-1.3 ... 25.0
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
-13 ... 250
-5.0 ... 100
Output 1
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
p-switching (PnP)
n-switching (nPn)
-13 ... 263
-5.0 ... 105
-1.3 ... 26.3
Permissible overl.
pressure
10 000 (10bar)
4 000
1 000 (1MPa)
Output 2
I: 4 ... 20 mA
U: 0 ... 10 V
Bursting
pressure
30 000 (30bar)
12 000
3 000 (3MPa)