Herunterladen Diese Seite drucken

SSS Siedle BTLE 050-04 Produktinformation Seite 5

Bus-einbautürlautsprecher

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
Application
Bus custom-fit door loudspeaker
for Siedle In-Home bus for on-site
intercom compartments, door con-
structions, letterboxes etc.
Volume controller for loudspeaker,
integrated video control, potential-
free working contact for the door
release. DR contact can be controlled
via the bus line without supple-
mentary wiring. Universal fastening
possibilities, when using with
louvre ZJ 051-... can be screwed on
directly.
1 BTLE 050-... corresponds to
2 system users.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Scope of supply
• Bus custom-fit door loudspeaker
BTLE 050-...
• This product information
Mounting
1a Dimensions of the BTLE 050-...
1b Position of microphone (Mic) and
loudspeaker (Ls)
1c Dimensions of the bus call button
matrix BRMA 050-...
The call button matrix can be fixed
in the housing using double-sided
adhesive tape or screws.
2 Mounting in letterbox systems
with intercom compartment. The
front panel must be detachable or
alternatively access afforded from
behind. Mount the bus custom-
fit door loudspeaker behind the
intercom opening (70 x 40 mm or
larger) using the fastening tabs or
holes. If fastened centrally, the tabs
can be broken off to save space.
Remarks
• The microphone and loud-
speaker have to lie flush with
the intercom louvre to prevent
feedback.
• The BTLE 050-... must not be laid
on the housing floor and must be
protected by the user where neces-
sary against the ingress of water.
Mounting with louvre ZJ 051-01
3 Breakthrough in the front panel,
W x H 71 x 50 mm
4 Insert the louvre and fasten.
5 At the BTLE 050-... replace the
two fastening screws 2.9 x 22 mm
by screws 2.9 x 16 mm. These are
enclosed with the louvre. Fasten the
BTLE 050-... to the louvre.
6 Press the Electret microphone tight
up against the front panel.
Installation
Installation, commissioning and pro-
gramming are described in the rel-
evant system manual and enclosed
with the line rectifier/server.
Commissioning
7 Volume control
Using the potentiometer, it is pos-
sible to change the volume to the
door. If acoustic feedback occurs,
the volume of the door loudspeaker
must be turned down.
8 The "Prog." button is used to
activate the programming mode.
Programming is described in the
system manual In-Home bus.
9 Connection of the BRMA 050-...
to BTLE 050-...
A maximum of 14 BRMA 050-...
units can be connected to one
BTLE 050-...
Servicing
Statutory warranty conditions apply.
Specifications
Contact type: 2 n.o. contacts
15 V AC/30 V DC, 2 A
Switching time: 3 sec
Protection system: Dependent on
the mounting conditions
Dimensions (mm) W x H x D:
124 x 60 x 31
Dimensions housing (mm)
W x H x D: 100 x 60 x 31
5