1
C
Mains and Controls separated
1-10V/DALI
1 : Main QPD 4P (M25)
2 : QPD 2P (M20)
1
2
Mains supply
1
2
Controls
1a
Mains and Controls combined
1-10V/DALI
Bi-power
1 : QPD 5P (M25)
1
No Dim
1 : QPD 4P (M25)
2
2a
TFLEX can be equipped with QPD connectors or cable glands (delivered with or without cable).
01-55-962 | DOC-0018754 rev G | 07-2023
QPD CONNECTORS
Lumgate
1 : Main QPD 4P (M25)
2 : M17 MSB (BUS IN - M20)
3 : M17 FSB (Bus OUT - M20)
CABLE GLANDS
1
2
www.schreder.com
2
3
1
LUMGATE
Male connector
M17
(IN- Pin)
1-10V / DALI
1:
Com+
3:
Com-
N:
Neutral
Female connector
M17
(OUT - Bus)
2:
Phase
Green/Yellow:
Marked earth
M25
M20
3
2/4