Herunterladen Diese Seite drucken

Konig & Meyer 26703 Kurzanleitung Seite 2

Sockelplatte

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

26703/04/05 Base plate
- The base plate for all common distance poles and
-
tube combinations with M20 threaded bolts
- Sturdy: solid and stable, it fulfills its purpose perfectly
- Appearance: elegant and very thin
- Practical: comes with a comfortable handle, large plug opening
-
and 4 feet covered in felt.
- Sophisticated: the tube combination can be set up according to your needs
Thank you for choosing this product. The instructions provide directions to all of the
important set up and handling steps. We recommend you keep these instructions for future
reference.
SAFETY NOTES
A. GENERAL
A.
- Weight bearing load (nominal load): depends on the K&M tube combination
A. -
(refer to Supplementary Sheet)
A.
- Assembly and handling only by qualified technicians
A.
- While mounting wear safety gloves
A.
- Only to be used indoors
A.
- Be sure that the surface will bear the load and is suitable and level
A.
- ATTENTION! The base plate is very heavy and improper use
A. -
can result in risk to individuals and objects
A. -
NOTE: in particular during assembly do not drop the base plate - or crush limbs
A.
- Base plate and tube combination must be screwed in as far as it goes
B. LATERAL FORCES
B.
- Lateral forces are to be avoided due to the risk of it falling over. This includes:
B. -
a. that the load bearing weight is not centered
B. -
b. and bumps, brushing into, vibration, wind, uneven surface
B. -
NOTE: Maintain safety distance, keep unauthorized persons away
B. -
Should the effectiveness of the measures not be guaranteed, (e.g. by not keeping
B. -
the safety distance and the safety distance cannot be guaranteed) the technicians
B. -
should secure the object with the following additional steps:
B.
- Anchor the base plate to the floor
B.
- Suitable extension/expansion/weighing down of the base plate
SET UP INSTRUCTIONS
1.a
Base plates with feet are to be placed feet down.
2.a
Threaded connector -M20 of the tube combination is to be screwed into the
2.a
baseplate as far as it will go.
2.a Ensure that a space is not left between the tube and the plate
2.a
NOTE: Regularly check and tighten the screws, if needed.
USAGE NOTES / FUNCTION
DIRECTION of the TUBE COMBINATION
- After the tube combination has been screwed in as far as it will go, the operation
-
elements could point in an undesired direction. This can be corrected.
- We recommend that two people are used for this: one person holds the plate and the
-
other person holds the tube
3 The counter nut on the underside of the plate are loosened with an ring spanner
4 The tube is moved back and forth a bit, so that the female threaded bolt can be
4
removed from the plate
5 Now turn the tube in the desired direction and feed the female threaded bolt into the plate
6 Place the counter nut in the proper position and tighten them with a ring spanner
HANDLE
7 The comfortable handle protects your hands and makes transport and installation
7
of the base plate easier and much safer.
FEET
To protect the floor the base plate has four screw-in feet that are covered in felt.
8 Loose feet must be tighten with a socket wrench (SW8 = M5).
CABLE / PLUG OPENING
19 Attractive appearance: The cables are laid underneath the base plate.
10 Technically on the safe side: the opening provides room for all standard plug types
10
and the plastic ring protects the cables against sharp edges.
FAULT-FINDING (F) and REPAIR (R)
F: The base plate rocks back and forth on the floor
F:
R: Check if the surface is even
F:
R: Base plate feet 8 are loose? Tighten with a socket wrench (SW8 = M5)
F: The tube combination is not sturdy i.e. is leaning to one side
F:
R: Check to ensure that the M-20 bolt is tight, Securely screw in the tube combination 2
F:
R: Counter nut 3 are loose? Tighten with ring spanner (SW40)
F:
R: Check to ensure the tube combination is straight
F:
R: Ensure that the surface is even
F: The tube combination is facing in the wrong direction
F:
R: Loosen the counter nut 3, Place the tube combination in the desired direction 5
F: R:
and secure the position by tightening the counter nut 6
TECHNICAL DATA
Plate, feet: Steel, powder-coated black
Threads: Steel, galvanized
Material
Cable protection: PA-6, black
Handle: TPE, black
Load capacity
depending on the tube combination, max.35 kg
W x D: 410 x 410 mm / 480 x 480 mm / 550 x 550 mm
Dimensions
Hight: 27 mm
Weight
7.5 kg / 10 kg / 14 kg
Accessories
Carrying case for base plate 24627-000-00
(optional)
Ring spanner SW40 26702-000-29
DIMENSIONS
SET UP INSTRUCTIONS
DIRECTION OF THE TUBE COMBINATION
HANDLE
CABLE / PLUG OPENING
26703/04/05-000-56/76 Rev.06/07/20/03 03-80-886-00 12/19
Optional available
26702-000-29 ring spanner
SW40
APPLICATION
EXAMPLE
FEET
KÖNIG & MEYER GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de

Werbung

loading

Diese Anleitung auch für:

2670426705