Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Betriebsanleitung Kompaktwaage
Operating instruction Compact balance
Mode d'emploi Balance compacte
KERN FOB
Version 1.9
05/2016
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
FOB-BA-def-1619

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für KERN & SOHN FOB 1K1M

  • Seite 1 KERN & Sohn GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www.kern-sohn.com Betriebsanleitung Kompaktwaage Operating instruction Compact balance Mode d'emploi Balance compacte KERN FOB Version 1.9 05/2016 FOB-BA-def-1619...
  • Seite 2 Weitere Sprachversionen finden Sie online unter www.kern-sohn.com/manuals Další jazykové verze najdete na webu pod adresou www.kern-sohn.com/manuals Yderligere sprogversioner finder de online på www.kern-sohn.com/manuals Más versiones de idiomas se encuentran online bajo www.kern-sohn.com/manuals Rohkem keeli internetis aadressil www.kern-sohn.com/manuals Vous trouverez d’autres versions de langue online sous www.kern-sohn.com/manuals Further language versions you will find online under www.kern-sohn.com/manuals A használati utasítás egyéb nyelveken a www.kern-sohn.com/manuals címről tölthető...
  • Seite 4: Inhaltsverzeichnis

    Akkubetrieb (optional)......................11 Erstinbetriebnahme ........................ 11 Justierung ..........................12 Justieren ..........................12 5.8.1 Eichfähige Modelle FOB 1K1M, FOB 2K2M, FOB 5K5M ............12 5.8.2 Eichfähige Modelle FOB 6K2LM, FOB 15K5LM, FOB 30K10LM ..........13 5.8.3 Nicht eichfähige Modelle ......................13 5.8.4...
  • Seite 5 Betrieb ......................18 Anzeigenübersicht ........................18 6.1.1 Eichfähige Modelle ........................18 6.1.2 Nicht eichfähige Modelle ......................18 Wägen ............................19 Tarieren............................ 19 Zero - Funktion ........................19 Plus/Minus-Wägungen ......................20 Netto-Gross-Wägungen ......................20 Auto-OFF-Modus ........................20 Fremdwägeeinheiten (nur Modelle FOB 1.5K0.5; FOB 3K1; FOB 6K2) ......20 Wartung, Instandhaltung, Entsorgung ............
  • Seite 6: Technische Daten

    1 Technische Daten 1.1 Elektronische Kompaktwaage (eichfähig) KERN FOB 1K1M FOB 2K2M FOB 5K5M Ablesbarkeit (d) Wägebereich (Max) 2 kg 5 kg Tarierbereich (subtraktiv) 2 kg 5 kg Empfohlenes Justiergewicht 1000 g (M1) 2000 g (M3) 5000 g (M3) (nicht beigegeben) (Klasse) Einschwingzeit (typisch) 2 sec.
  • Seite 7 KERN FOB 6K2LM FOB 15K5LM FOB 30K10LM Ablesbarkeit (d) 10 g Wägebereich (Max) 6 kg 15 kg 30 kg Tarierbereich (subtraktiv) 6 kg 15 kg 30 kg Reproduzierbarkeit 10 g Linearität ± 4 g ± 10 g ± 20 g Empfohlenes Justiergewicht 5 kg (M2) 10 kg (M3)
  • Seite 8: Elektronische Kompaktwaage (Nicht Eichfähig)

    1.2 Elektronische Kompaktwaage (nicht eichfähig) KERN FOB 1.5K0.5 FOB 3K1 FOB 6K2 Ablesbarkeit (d) 0,5 g Wägebereich 1,5 kg 3 kg 6 kg Tarierbereich (subtraktiv) 1,5 kg 3 kg 6 kg Reproduzierbarkeit 0,5 g Linearität ± 1 g ± 2 g ±...
  • Seite 9 KERN FOB 7.5K0.5L FOB 15K1L FOB 30K2L Ablesbarkeit (d) 0,5 g Wägebereich 7,5 kg 15 kg 30 kg Tarierbereich (subtraktiv) 7,5 kg 15 kg 30 kg Reproduzierbarkeit 0,5 g Linearität ± 1,5 g ± 3 g ± 6 g Empfohlenes Justiergewicht 5 kg (M1) 10 kg (M1) 20 kg (M1)
  • Seite 10: Grundlegende Hinweise (Allgemeines)

    2 Grundlegende Hinweise (Allgemeines) 2.1 Bestimmungsgemäße Verwendung Die von Ihnen erworbene Waage dient zum Bestimmen des Wägewertes von Wägegut. Sie ist zur Verwendung als „nichtselbsttätige Waage“ vorgesehen, d.h. das Wägegut wird manuell, vorsichtig und mittig auf die Wägeplatte aufgebracht. Nach Erreichen eines stabilen Wägewertes kann der Wägewert abgelesen werden.
  • Seite 11: Prüfmittelüberwachung

    2.4 Prüfmittelüberwachung Im Rahmen der Qualitätssicherung müssen die messtechnischen Eigenschaften der Waage und eines eventuell vorhandenen Prüfgewichtes in regelmäßigen Abständen überprüft werden. Der verantwortliche Benutzer hat hierfür ein geeignetes Intervall sowie die Art und den Umfang dieser Prüfung zu definieren. Informationen bezüglich der Prüfmittelüberwachung von Waagen sowie die hierfür notwendigen Prüfgewichte sind der KERN-Hompage...
  • Seite 12: Auspacken, Aufstellung Und Inbetriebnahme

    5 Auspacken, Aufstellung und Inbetriebnahme 5.1 Aufstellort, Einsatzort Die Waagen sind so konstruiert, dass unter den üblichen Einsatzbedingungen zuverlässige Wägeergebnisse erzielt werden. Exakt und schnell arbeiten Sie, wenn Sie den richtigen Standort für Ihre Waage wählen. Beachten Sie deshalb am Aufstellort folgendes: Waage auf eine stabile, gerade Fläche stellen;...
  • Seite 13: Auspacken

    5.2 Auspacken Die Waage vorsichtig aus der Verpackung nehmen, Plastikhülle entfernen und die Waage am vorgesehenen Arbeitsplatz aufstellen. 5.3 Aufstellen Die Waage mit Fußschrauben nivellieren, bis sich die Luftblase in der Libelle im vorgeschriebenen Kreis befindet. Hinweis: Bei nicht eichfähigen Modellen befindet sich die Libelle unter der Wägeplatte.
  • Seite 14: Justierung

    (siehe Kap. 6.8 Eichung). Stabile Umgebungsbedingungen beachten. Eine kurze Anwärmzeit von ca. 5 Minuten zur Stabilisierung sind zweckmäßig. 5.8.1 Eichfähige Modelle FOB 1K1M, FOB 2K2M, FOB 5K5M  Waage mit -Taste einschalten.  Justierschalter an der Waagenunterseite (siehe Kap. 6.7.4) zwei mal betätigen.
  • Seite 15: Eichfähige Modelle Fob 6K2Lm, Fob 15K5Lm, Fob 30K10Lm

    Justiergewicht von der Wägeplatte abnehmen, die Justierung ist beendet 5.8.4 Überprüfung der Software-Einstellungen bezügl. der Eichung einer Waage (nur für Modelle FOB 1K1M, FOB 2K2M, FOB 5K5M): Für die Justagefunktion muss die Waage in einen Servicemode umgeschaltet werden. Dieser Servicemode wird durch zweimaliges betätigen des Justierschalters aktiviert.
  • Seite 16 Übersicht der Softwareeinstellmöglichkeiten: Navigation Menü Press TARE 3sec GROSS Overload setting by hardware option A_OFF divS GrAv trAn trAtE trAd 2400 4800 9600 19200 md-1 md-2 0.5g 0.2g 0.5g 0.01 0.005 0.002 10.0 15.0 FOB-BA-d-1619...
  • Seite 17: Position Justierschalter (Eichf. Modelle)

    Ist die TRAD-Einstellung auf OFF, so muss diese vor einer Eichung auf ON gestellt werden. Zurücksetzen in eichfähige Einstellung: Drücken Sie die Taste und halten diese gedrückt bis „A_OFF“ im Display erscheint. Drücken Sie die -Taste wiederholt bis „TRAD“ erscheint.. Jetzt -Taste drücken, im Display erscheint „OFF“.
  • Seite 18: Eichung

    5.9 Eichung Allgemeines: Nach der EU-Richtlinie 90/384/EWG müssen Waagen geeicht sein, wenn sie wie folgt verwendet werden (gesetzlich geregelter Bereich): a) Im geschäftlichen Verkehr, wenn der Preis einer Ware durch Wägung bestimmt wird. b) Bei der Herstellung von Arzneimitteln in Apotheken sowie bei Analysen im medizinischen und pharmazeutischen Labor.
  • Seite 19: Position Der „Siegelmarken

    5.9.1 Position der „Siegelmarken” Die Eichung der Waage ist ohne die „Siegelmarken“ ungültig. Position der „Siegelmarken“: Siegelmarken (Je nach Modell) Eichpflichtige Waagen müssen außer Betrieb gesetzt werden, wenn: Das Wägeergebnis der Waage außerhalb der Verkehrsfehlergrenze liegt. Waage deshalb in regelmäßigen Abständen mit bekanntem Prüfgewicht (ca. 1/3 der Nennlast) belasten und mit Anzeigenwert vergleichen.
  • Seite 20: Betrieb

    6 Betrieb 6.1 Anzeigenübersicht 6.1.1 Eichfähige Modelle FOB 1K1M, FOB 2K2M, FOB 5K5M: FOB 6K2LM, FOB 15K5LM, FOB 30K10LM: 6.1.2 Nicht eichfähige Modelle FOB 1.5K0.5, FOB 3K1, FOB 6K2: FOB 7.5K0.5L; FOB 15K1L; FOB 30K2L: FOB-BA-d-1619...
  • Seite 21: Wägen

    6.2 Wägen Waage mit Taste einschalten. Waage zeigt für etwa 3 Sekunden „88888“ im Display und geht dann auf „0“. Nun ist sie betriebsbereit. Wichtig: Sollte die Anzeige blinken oder nicht auf „0“ stehen, Taste oder Taste drücken (siehe Kapitel 7.2.2 od. 7.2.3) Erst jetzt (!) Wägegut auf die Wägeplatte legen.
  • Seite 22: Plus/Minus-Wägungen

    6.5 Plus/Minus-Wägungen Zum Beispiel zur Stückgewichtskontrolle, Fertigungskontrolle usw. Waage mit Taste einschalten und „0“-Anzeige abwarten. Sollgewicht auf Wägeplatte und mit Taste auf „0“ tarieren. Sollgewicht abnehmen. Prüflinge nacheinander auf die Wägeplatte, jeweilige Abweichung zum Sollgewicht wird vorzeichenrichtig nach „+“(*) und „-“ angezeigt *(bei „+“...
  • Seite 23: Wartung, Instandhaltung, Entsorgung

    7 Wartung, Instandhaltung, Entsorgung 7.1 Reinigen Vor der Reinigung trennen Sie das Gerät bitte von der Betriebsspannung. Benutzen Sie bitte keine aggressiven Reinigungsmittel (Lösungsmittel o.ä.), sondern nur ein mit milder Seifenlauge angefeuchtetes Tuch. Achten Sie darauf, dass keine Flüssigkeit in das Gerät eindringt und reiben Sie mit einem trockenen, weichen Tuch nach.
  • Seite 24: Kleine Pannenhilfe

    8 Kleine Pannenhilfe Bei einer Störung im Programmablauf sollte die Waage kurz ausgeschaltet und vom Netz getrennt werden. Der Wägevorgang muss dann wieder von vorne begonnen werden. Hilfe: Störung Mögliche Ursache • Die Waage ist nicht eingeschaltet. Die Gewichtsanzeige leuchtet nicht. •...
  • Seite 25: Konformitätserklärung

    9 Konformitätserklärung Die aktuelle EG/EU-Konformitätserklärung finden Sie online unter: www.kern-sohn.com/ce Bei geeichten Waagen (= konformitätsbewerteten Waagen) ist die Konformitätserklärung im Lieferumfang enthalten. FOB-BA-d-1619...
  • Seite 26 Hinweis gemäß Batterieverordnung – BattV QYP 05 (Rev. 1.0) Nur gültig für Deutschland! Im Zusammenhang mit dem Vertrieb von Batterien und Akkus sind wir als Händler gemäß Batterieverordnung verpflichtet, Endverbraucher auf folgendes hinzuweisen: Endverbraucher sind zur Rückgabe gebrauchter Batterien/Akkus gesetzlich verpflichtet.
  • Seite 28 Rechargeable battery operation (optional) ................11 Initial start-up .......................... 11 Adjustment ..........................12 Adjusting ..........................12 5.7.1 Verifiable Models FOB 1K1M, FOB 2K2M, FOB 5K5M ............12 5.7.2 Verifiable Models FOB 6K2LM, FOB 15K5LM, FOB 30K10LM ..........12 5.7.3 Non-verifiable Models ....................... 13 5.7.4...
  • Seite 29 Operation ...................... 17 Overview of display ........................ 17 6.1.1 Verifiable models ........................17 6.1.2 Non-verifiable models ....................... 17 Weighing ..........................18 Taring ( key) ........................18 Zeroing the balance ( ->verifiable balances) ..............18 Plus/minus weighings ......................19 Net/gross weighings ......................19 Auto OFF mode ........................
  • Seite 30: Technical Data

    Technical data Verifiable models KERN FOB 1K1M FOB 2K2M FOB 5K5M Readout (d) Weighing range 2 kg 5 kg Taring range (subtractive) 2 kg 5 kg Adjustmentweight 1000g (M1) 2000 g (M3) 5000 g (M3) (not included) (class) Stabilization time 2 sec.
  • Seite 31 KERN FOB 6K2LM FOB 15K5LM FOB 30K10LM Readout (d) Weighing range (Max) 6 kg 15 kg 30 kg Taring range (subtractive) 6 kg 15 kg 30 kg Reproduzierbarkeit 10 g Linearität ± 4 g ± 10 g ± 20 g Adjustmentweight 5 kg (M3) 10 kg (M3)
  • Seite 32: Non Verifiable Models

    1.2 Non verifiable models KERN FOB 1.5K0.5 FOB 3K1 FOB 6K2 Readout (d) 0,5 g Weighing range 1,5 kg 3 kg 6 kg Taring range (subtractive) 1,5 kg 3 kg 6 kg Reproducibility 0,5 g Linearity ± 1 g ± 2 g ±...
  • Seite 33 KERN FOB 7.5K0.5L FOB 15K1L FOB 30K2L Readout (d) 0,5 g Weighing range 7,5 kg 15 kg 30 kg Taring range (subtractive) 7,5 kg 15 kg 30 kg Reproduzierbarkeit 0,5 g Linearität ± 1,5 g ± 3 g ± 6 g Adjustmentweight 5 kg (M1) 10 kg (M1)
  • Seite 34: Fundamental Information (General)

    Fundamental information (general) Intended use The balance you have acquired serves to determine the weighing value of the mate- rial to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate.
  • Seite 35: Monitoring The Test Substances

    Monitoring the test substances The metrology features of the balance and any possible available adjusting weight must be checked at regular intervals within the scope of quality assurance. For this purpose, the answerable user must define a suitable interval as well as the nature and scope of this check.
  • Seite 36: Unpacking, Installation And Commissioning

    5 Unpacking, installation and commissioning Place of installation, place of use The balance is constructed in such a way that reliable weighing results can be achieved under normal application conditions. By selecting the correct location for your balance, you will be able to work quickly and precisely.
  • Seite 37: Installation

    Installation Use the foot screws to level the balance until the air bubble in the bubble level is in the prescribed circle. Notice : With non-verifiable models the air bubble is below the weighing plate. 5.2.1 List of items supplied Standard accessories: Balance Weighing pan...
  • Seite 38: Adjustment

    (see chpt. 6.8 calibration). Observe stable environment conditions. A short warming-up period of about 5 minutes for stabilization is useful. 5.7.1 Verifiable Models FOB 1K1M, FOB 2K2M, FOB 5K5M  Switch the balance on using the key.  Press the adjust switch at the lower surface (see chap. 6.7.4) twice. A numeri- cal value will appear on the display.
  • Seite 39: Non-Verifiable Models

     Remove the adjusting weight from the weighing plate to complete adjusting. 5.7.4 Check software settings for verification of a balance (only models FOB 1K1M, FOB 2K2M, FOB 5K5M): For the adjustment function, the balance must be switched over to a service mode.
  • Seite 40 Overview of the possible software settings: (there may be small differences referring to the model): Navigation Menu Press TARE 3sec GROSS Overload setting by hardware option A_OFF divS GrAv trAn trAtE trAd 2400 4800 9600 19200 md-1 md-2 0.5g 0.2g 0.5g 0.01 0.005...
  • Seite 41: Position Adjust Switch

    5.7.5 Position adjust switch Adjust switch at the lower surface (depending on the model, on the right or the left side) Verification General: According to the EU guideline 90/384/EEC balances must be verified if they are to be used as follows (legally regulated area): a) For commercial transactions if the price of goods is determined by weighing b) For the production of medines in pharmacies as well as for analyses in the medical and pharmaceutical laboratory...
  • Seite 42: Position Of The „Security Marks

    5.8.1 Position of the „security marks“ The adjustment switch is inside the balance. After the verification process the balance is sealed on the marked positions. The verification of the balance is not valid without the security mark. Position of the „security marks“: Security marks (depend- ing on the model) Balances that are subject to compulsory verification must be taken out of...
  • Seite 43: Operation

    6 Operation Overview of display 6.1.1 Verifiable models FOB 1K1M, FOB 2K2M, FOB 5K5M: FOB 6K2LM; FOB 15K5LM; FOB 30K10LM: 6.1.2 Non-verifiable models FOB 1.5K0.5, FOB 3K1, FOB 6K2: FOB 7.5K0.5L; FOB 15K1L; FOB 30K2L: FOB-BA-e-1619...
  • Seite 44: Weighing

    6.2 Weighing Switch the balance on by pressing the key. The balance will show “88888“ for approx. 3 seconds and then change to “0“. Now it is ready for use. Important: If the display does not show “0“ press the (details in capture 7.2.2 or 7.2.3).
  • Seite 45: Plus/Minus Weighings

    6.5 Plus/minus weighings For example in order to check a single weight or for production control, etc. Switch the balance on using the key and wait until “0” appears on the display. Place the target weight on the weighing plate and tare to “0” using the key.
  • Seite 46: Maintenance, Upkeep, Disposal

    7 Maintenance, upkeep, disposal Cleaning Please disconnect the device from the operating voltage before cleaning. Only use a cloth dampened with mild suds and not aggressive cleaning agents (sol- vents or similar). Please ensure that fluids are not able to get into the device and rub off using a clean, soft cloth.
  • Seite 47: Troubleshooting

    8 Troubleshooting The balance should be switched off for a short time following an interruption in the programme sequence and disconnected from the mains supply. It is then necessary to repeat the weighing process from the beginning. Help: Interruption Possible cause •...
  • Seite 48: Declaration Of Conformity

    9 Declaration of Conformity To view the current EC/EU Declaration of Conformity go to: www.kern-sohn.com/ce The scope of delivery for verified weighing balances (= conformity- rated weighing balances) includes a Declaration of Conformity. FOB-BA-e-1619...
  • Seite 50 Fonctionnement de la pile rechargeable (en option) ............11 Première mise en service....................... 11 Ajustage ........................... 12 Ajuster ............................. 12 5.8.1 Vérifiable modèles FOB 1K1M, FOB 2K2M, FOB 5K5M ............12 5.8.2 Vérifiable modèles FOB 6K2LM, FOB 15K5LM, FOB 30K10LM ..........12 5.8.3 Non vérifiable modèles ......................13 5.8.4...
  • Seite 51 Fonctionnement ................... 17 Vue d’ensemble des affichages .................... 17 6.1.1 Modèles admis à la vérification ....................17 6.1.2 Modèles non admis à la vérification ..................17 Pesage ............................. 18 Tarage (touche ) ........................ 18 Mettre la balance à zéro (touche , modèles admis à...
  • Seite 52: Données Techniques

    1 Données techniques 1.1 Modèles admis à la vérification KERN FOB 1K1M FOB 2K2M FOB 5K5M Lecture (d) Portée 2 kg 5 kg Amplitude de tarage 2 kg 5 kg (soustractive) Poids d‘ajustage 1000 g (M1) 2.000 g (M3) 5.000 g (M3)
  • Seite 53 KERN FOB 6K2LM FOB 15K5LM FOB 30K10LM Lecture (d) 10 g Portée (Max) 6 kg 15 kg 30 kg Amplitude de tarage 6 kg 15 kg 30 kg (soustractive) Reproductibilité 10 g Linéarité ± 4 g ± 10 g ± 20 g Poids d‘ajustage 5 kg (M2) 10 kg (M2)
  • Seite 54: Modèles Non Admis À La Vérification

    1.2 Modèles non admis à la vérification KERN FOB 1.5K0.5 FOB 3K1 FOB 6K2 Lecture (d) 0,5 g Portée 1,5 kg 3 kg 6 kg Amplitude de tarage 1,5 kg 3 kg 6 kg (soustractive) Reproductibilité 0,5 g Linéarité ± 1 g ±...
  • Seite 55 KERN FOB 7.5K0.5L FOB 15K1L FOB 30K2L Lecture (d) 0,5 g Portée 7,5 kg 15 kg 30 kg Amplitude de tarage 7,5 kg 15 kg 30 kg (soustractive) Reproductibilité 0,5 g Linéarité ± 1,5 g ± 3 g ± 6 g Poids d‘ajustage 5 kg (M1) 10 kg (M1)
  • Seite 56: Indications Fondamentales (Généralités)

    2 Indications fondamentales (généralités) 2.1 Utilisation conforme à la destination de l´appareil La balance que vous avez achetée sert à la détermination de la valeur de pesée de matières devant être pesées. Elle est conçue pour être utilisée comme „balance non automatique“, c´à...
  • Seite 57: Vérification Des Moyens De Contrôle

    2.4 Vérification des moyens de contrôle Les propriétés techniques de mesure de la balance et du poids de contrôle éventuel- lement utilisé doivent être contrôlées à intervalles réguliers dans le cadre des con- trôles d´assurance qualité. A cette fin, l´utilisateur responsable doit définir un inter- valle de temps approprié...
  • Seite 58: Déballage, Installation Et Mise En Service

    5 Déballage, installation et mise en service 5.1 Lieu d´installation, lieu d´utilisation La balance a été construite de manière à pouvoir obtenir des résultats de pesée fiables dans les conditions d´utilisation d´usage. Vous pouvez travailler rapidement et avec précision à condition d´installer votre ba- lance à...
  • Seite 59: Installation

    5.2 Installation Procéder à la mise à niveau de la balance à l´aide des vis des pieds, jusqu´à ce que la bulle d´air du niveau se trouve dans le cercle prescrit. La balance doit être installée de manière à ce que le plateau de pesée soit placé exactement à...
  • Seite 60: Ajustage

    Veillez à avoir des conditions environnementales stables. Un bref temps de réchauf- fage d’env. 5 minutes est judicieux pour la stabilisation. 5.8.1 Vérifiable modèles FOB 1K1M, FOB 2K2M, FOB 5K5M  Mettre en marche la balance avec la touche  Utilisez 2 fois le commutateur d'ajustage sous la balance (Voyez chapitre 6.7.4).
  • Seite 61: Non Vérifiable Modèles

     Retirer le poids d’ajustage du plateau de pesée, l’ajustage est terminé. 5.8.4 Contrôle des réglages du logiciel pour l’étalonnage d’une balance (seulement modèles FOB 1K1M, FOB 2K2M, FOB 5K5M): Pour la fonction d’ajustage, la balance doit être commutée dans un mode de service.
  • Seite 62 Vue d’ensemble des possibilités de réglage du logiciel (il y peut avoir des petites différences se référant au modèle): Navigation menu Press TARE 3sec GROSS Overload setting by hardware option A_OFF divS GrAv trAn trAtE trAd 2400 4800 9600 19200 md-1 md-2 0.5g...
  • Seite 63: Position Commutateur D'ajustage

    5.8.5 Position commutateur d'ajustage Commutateur d'ajustage sous la balance (selon le modèle sur le côté gauche ou droit) 5.9 Vérification Généralités: D´après la directive UE 90/384/CEE, les balances doivent faire l´objet d´un vérifica- tion lorsqu´elles sont utilisées tel qu´indiqué ci-dessous (domaine régi par la loi): a) Dans le cadre de relations commerciales, lorsque le prix d´une marchandise est déterminé...
  • Seite 64: Position Des "Marques De Sécurité

    5.9.1 Position des "Marques de sécurité" La vérification de la balance n’est pas valable sans "Marques de sécurité". Position des "Marques de sécurité": Marque de sécurité ( selon le modèle) Les balances soumises à l´obligation de vérification doivent être arrêtées lorsque: Le résultat de pesée de la balance dépasse la limite de sécurité...
  • Seite 65: Fonctionnement

    6 Fonctionnement 6.1 Vue d’ensemble des affichages 6.1.1 Modèles admis à la vérification FOB 1K1M, FOB 2K2M, FOB 5K5M: FOB 6K2LM, FOB 15K5LM, FOB 30K10LM: 6.1.2 Modèles non admis à la vérification FOB 1.5K0.5, FOB 3K1, FOB 6K2: FOB 7.5K0.5L; FOB 15K1L; FOB 30K2L:...
  • Seite 66: Pesage

    6.2 Pesage Allumer la balance en appuyant sur L’indication « 88888 » apparaît pendant environ trois secondes, puis un « 0 » s’affiche : la balance est prête à fonctionner. Important: Si l'affichage clignote ou n'affiche pas "0" , pressez la touche ( voyez chapitre 7.3 ou 7.4) Ensuite, poser l’objet sur le plateau.
  • Seite 67: Pesées Nettes En Gros

    Mettre la balance en marche avec la touche et attendre que l’écran de visualisa- tion affiche „0“. Tarer le poids de référence sur le plateau de pesée à l’aide de la touche , de ma- nière à ce l’écran de visualisation affiche „0“. Retirer le poids de référence. Placer les échantillons les uns après les autres sur le plateau de pesée, toute dévia- tion par rapport au poids de référence s’affiche précédée des signes correspondants „+“(*) et „-“...
  • Seite 68: Maintenance, Entretien, Élimination

    7 Maintenance, entretien, élimination 7.1 Nettoyage Avant le nettoyage, coupez l´appareil de la tension de fonctionnement. N´utilisez pas de produits de nettoyage agressifs (dissolvants ou produits similaires) mais uniquement un chiffon humidifié avec de la lessive de savon douce. Veillez à ce que les liquides ne puissent pas pénétrer dans l´appareil et frottez ensuite ce der- nier avec un chiffon doux sec.
  • Seite 69: Aide Succincte En Cas De Panne

    8 Aide succincte en cas de panne En cas d´anomalie dans le déroulement du programme, la balance doit être arrêtée pendant un court laps de temps et coupée du secteur. Le processus de pesée doit alors être recommencé depuis le début. Aide: Anomalie Cause possible...
  • Seite 70: Déclaration De Conformité

    9 Déclaration de conformité Vous trouvez la déclaration de conformité CE- UE actuelle online sous: www.kern-sohn.com/ce Dans le cas de balances étalonnées (= de balances à la conformité évaluée) la déclaration de conformité est comprise dans les fourni- tures. FOB-BA-f-1619...