3.7 Error Codes
Code
Error message
F1
Battery Protection (Over- or Undervoltage)
F2
Fan Safety Shut Down
F3
Protection mode for frequently used compressor Please contact the customer service
F4
Cooling System Overload
Thermal Protection Cooling System or Ambient
F5
Temperature
F6
Hardware Failure
F7
Temperature Sensor Short Circuit
F8
Temperature Sensor Open Circuit
Plug-in Festivals GmbH, Benutzerhandbuch IceCube DUAL (2023)
Trouble shooting
Please check the power supply or change
the battery protection mode
Please check the ventilation holes for any
foreign objects or dirt Check if the fan can
spin free. Cut the device from the
power supply and let it
cool down for one hour.
If the problem still comes
up, contact the customer
service
Cut the device from the power supply and
let it cool down for one hour. If the
problem still comes up, contact the
customer service
Cut the device from the power supply and
let it cool down for one hour. If the
problem still comes up, contact the
customer service.
Cut the device from the power supply and
contact the customer service
Cut the device from the power supply and
contact the customer service
Cut the device from the power supply and
contact the customer service