◆Humidity measuring range: 0~99%
◆Resolution: 0.1℃; 0.1%
◆Accuracy: ±1.0℃;±5%
◆Time unit: hour (24:00 format)
◆Relay Capacity: 10A/220V
◆Input voltage: 220V±15%(VAC),50HZ~60HZ
◆Product consumption: ≤3W
◆Outputs: resistive load≤1100W/220V, inductive load≤275W/220V, filament lamp≤220W/220V
Button:
∧: up adjust; ∨:down adjust; SET: set
Symbol:
Flash: compressor delay; display: cool working; no display: cool stopped working.
Display: heat working; no display: heat stopped working.
Display: humidification working; no display: humidification stopped working.
Display: dehumidification working; no display: dehumidification stopped working.
Display: daytime; no display: nighttime.
Display: nighttime; no display: daytime.
Rapid flash: high temp alarm or low temp alarm.
Rapid flash: high humidity alarm or low humidity alarm.
Temperature Menu Instructions:
Menu item
HEAT/COOL(MODE): M
DAY SET: day temp setting
Night SET: night temp setting
DIFFERENCE
ALARM
Humidity Menu Instructions:
Menu item
HUMI/ DEHUMI (MODE): M
DAY SET: day humidity setting
Night SET: night humidity setting
DIFFERENCE
ALARM
Parameters setting:
Parameters would be set according to the following circular mode in the first time; All the parameters are set and saved instantly.
First of all, make sure the power is on.
1. Choose HEAT/COOL mode:
RT : real-time temperature;
Press SET key for 3 seconds to enter into setting mode
When H EAT f lashing, press UP or DOWN key to choose mode between H EAT and C OOL .
2. DAY SET: day temp setting
Press SET key to display the default temperature value while icon D AY SET f lashing, then press UP or DOWN key to adjust the ideal temperature
you want for daytime.
3. NIGHT SET: night temp setting
Press SET key to display the default temperature value while icon N IGHT SET f lashing, then press UP or DOWN key to adjust the ideal
temperature you want for nighttime.
4. DIFFERENCE (for temperature):
Press SET key to display the default temperature value while icon D IFFERENCE f lashing, then press UP or DOWN key to adjust the ideal
temperature difference you want.
5. ALARM (for temperature):
Press SET key to display the default temperature value while icon A LARM f lashing, then press UP or DOWN key to adjust the ideal temperature
alarm difference you want.
6. Choose HUMI/DEHUMI mode:
RH : real-time relative humidity
Press SET key to display the default humidity mode while icon H UMI f lashing, press UP or DOWN key to choose mode between H UMI and
DEHUMI .
7. DAY SET: day humidity setting
Press SET key to display the default humidity value while icon D AY SET f lashing, then press UP or DOWN key to adjust the ideal humidity you
want for daytime.
8. NIGHT SET: night humidity s etting
Press SET key to display the default humidity value while icon N IGHT SET f lashing, then press UP or DOWN key to adjust the ideal humidity you
want for nighttime.
9. DIFFERENCE (for humidity):
Set
Default
COOL /HEAT
HEAT
16.0~42.0℃
30.0℃
16.0~42.0℃
22.0℃
0.1~9.9
2.0℃
1~10
5℃
Set
Default
HUMI/ DEHUMI
HUMI
1~99%
50%
1~99%
60%
1~20
5%
1~30
10%
Remark
COOL mode delay 1 min.
Set step 0.1℃
Set step 0.1℃
Set step 0.1℃
Remark
Set step 1%
3