Herunterladen Diese Seite drucken

DRYDEN AQUA DA-GEN Bedienungsanleitung Seite 4

Vorschau ausblenden Andere Handbücher für DA-GEN:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
1
11
4
8
2
10
9
3
6
5
13
14
A
External pump controller*
B
Filter with AFM
®
C
Filter pump
1
Control Panel
2
Free chlorine cell with rotameter
3
Cell
(always in vertical position if installed without paddle
6
flow switch
)
4
pH probe
5
Redox probe and/or conductivity probe
Conductivity probe
1
yellow
2
transparent
Cover
1
&
5
Chlorine probe detector
FL2
(rotameter)
3
black
5
brown
6
blue
Paddle Flow switch
FL1
2
5
&
Suction lance pH-
Minus
4
&
5
TANK
Temperature probe
1
red
2
yellow
3
black
AUX 1
Dosing pump flocculation
pH
APF
®
3
pH dosing pump
1
2
&
3. SYSTEM INSTALLATION
15
B
12
6
Paddle flow switch and temperature module
7
APF
®
dosing pump
8
pH dosing pump
9
pH injection
10
Prefilter
11
Wifi module
12
APF
®
(not included)
13
pH-Minus
(not included)
14
If Outdoor pool: ACO
(not included)
15
Besgo valve
(not included)
4. ELECTRICAL CONNECTIONS
CONNECT ALL THE SENSORS CAREFULLY, A
BAD CONNECTION MAY CAUSE IRREPARABLE
DAMAGE TO THE DEVICE
1
110-230 V
max. 3.15 A
2
1 2 3 4 5 6
1
2
3
4
5
6
7
8
1 2 3
AUX 2
Besgo backwash
4
&
valve
5
&
6
A
7
C
Variable Rate Pump
®
DRY CONTACT
7 8 9
10 11 12 13 14
Free chlorine
3
4
red
black
N
L
A1 A2
14
11
12
FILTER PUMP
LIGHT
Filtration control
Lighting control
9
10
&
7
8
&
2
Electrical consumption
Use of a 13 Amp time delay circuit breaker is recommended
for private devices and a 16 A breaker for public devices.
In case of sharing the power supply with other devices
please consult a technician in order to dimension a correct
installation.
Maximum
Product
consumption
Product
DA-GEN 24
90 W
DA-GEN 240
DA-GEN 45
125 W
DA-GEN 360
DA-GEN 90
180 W
DA-GEN 500
DA-GEN 150
DA-GEN 750
175 W
Private
* Filtration control by external timer
Filtration mode:
"Manual/ON"
230 V
* Filtration control by internal timer
Filtration mode:
Automatic
see Chapter 12
LINKS TO FILTER PUMP
230 V
1 2 3 4
Variable speed pump
1
1
3
2
3
Device control SLAVE
4
1
1
2
1
2
3
Connection ext. display*
3
Connection WIFI module
4
1
3
1
redoX
pH
AUX 3
AUX 4
ACO
®
Heating control
11
13
14
&
12
&
Maximum
consumption
680 W
1000 W
1020 W
2880 W
Public
slow
2
medium
fast
4
common
brown
2
blue
3
2
red
2
yellow
green
4
black
*IF connecting 2 displays on
the device, remember not to
connect the second display in
this communication channel.
Use the "ext. Display" socket
instead.
EN

Werbung

loading