DA-GEN
Dryden Aqua Generator
USER MANUAL
The DA-GEN is an innovative water treatment system and additional an intelligent pool controller. The DA-GEN
combines Hydrolysis with Electrolysis with a low mineral content.
The Hydrolysis produces free radicals and other oxygen compounds like ozone, peroxide and persulfate. All
these oxidants destroy organic substances and pathogens in the water. Free radicals are the strongest oxidants
we know. They oxidise and decompose in a few seconds. To guarantee a safe residual disinfection the DA-GEN
produces a very small amount of chlorine. In combination with Dryden DAISY
content of 1 to 2 kg MgCl
or 0.75 to 1.5 kg NaCl per m
2
The DA-GEN also controls all your pool equipment centrally. Thanks to WiFi you can check and control your pool
system 24/7.
Control panel
4
1
2
3
110-230 V
1
Connection cell
Gas detector connection
2
5
3
Main 230V connection
6
4
ON/OFF switch
Heating ON/OFF
Status of the auxiliary relays
Current time
Production intensity
in %
(normally 40-100%)
Automatic measurements: pH/redoX/
free chlorine/conductivity
(according to options)
Status of filtration relay
(see chapter 12- Filtration)
man
Manual
aut
Automatic
Communication display – mother board
PLUS key
MINUS key
Modify value/selection
Modify value/selection
Shortcut Backwash
Shortcut Light
(press 3s)
(press 3s)
1. DESCRIPTION
3
.
5
6
4 Amp fuse for panel and cell
4 Amp fuse relays
2. MAIN SCREEN
12:30
1 2 3 4
hydrolysis
100
%
measures
7.4
pH
700
Rx
mV
0.30
Cl
ppm
man
off
OK key
Select/confirm
®
we need a very low mineral
Cell
4
1
5
2
Water temperature
If the cover is open the filtration speed is "medium" (if with
Cover
frequency controlled pump)
Polarity 1 /
Pol 1
Waiting time
---
Filtration stopped due to lack of water flow
Flow
25º
Lack of conductivity or salt / low water temperature / scale on
Low
cell / exhausted cell
Pol 1
Cover
LOW
7.4 OFF
7.0
AL3
7.4
pH Setpoint
700 OFF
Function of pH dosing pump
FL1
AL3
ON/OFF
0.30 FL2
AL3
Maximum dosing time exceeded
FL1
TANK
7.0
Setpoint pH minimum (if using pH-Minus and pH-Plus)
man
off
Additional chlorine pump (optional)
ON/OFF
FL 1
Flow alarm (Paddle/Gas)
700
Minimum Redox Setpoint
Maximum dosing time exceeded
AL3
0.30
Free Chlorine Minimum Setpoint
FL 1
Flow alarm (Paddle/Gas) /
AL3
Maximum dosing time exceeded
TANK
Low level pH-Minus bottle
Lights
Manual /
Automatic
man
aut
UP key
Navigation up
1
1
Cell
2
Gas detector connector
3
Cell connector
3
Cell housing
4
5
Gas detector (internal)
1
Except DA-GEN 150
Polarity 2
Pol 2
(check working hours)
(
to reset the alarm)
(
to reset the alarm)
Flow alarm rotameter Cl
FL 2
(
to reset the alarm)
RETURN/ESCAPE
DOWN key
key
Navigation down
1
2
EN