Charge 4Ah – 550Ah (Manual)
Supports all batteries from a minimum of 4Ah up to a maximum of 550Ah. Possibility of adjusting the output current
from 0 up to the maximum supported by the operating mode currently selected on the battery charger.
Charge 150Ah - 300 Ah
Supports batteries from 150Ah up to 300Ah. Output current adjusted automatically.
Charge 80 Ah - 150 Ah
Supports batteries from 80Ah up to 150Ah. Output current adjusted automatically.
Charge 30 Ah - 80 Ah
Supports batteries from 30Ah up to 80Ah. Output current adjusted automatically.
C) Supported Batteries: "Battery Type"
Wet
Acid electrolyte batteries.
Agm-Spiral Cell
AGM batteries with flat plate or Optima type spiral cell.
Saving settings
The battery charger saves the settings made on the front control panel. In the event of an accidental power loss or
voluntary power off, when it is repowered the battery charger will restart with the latest saved settings, also of the
"Start / Stop" status.
Battery Analysis
The analysis stages within the operating modes may terminate with the signalling of various errors.
Damaged Battery: the "Fault" LED switches on and the ''Start / Stop'' LED switches off and the battery
charger enters Stand-By mode. The display shows the message ''Errx'' where "x" is the number
corresponding to the cause of the error (see table 1). Single two second audible signal.
Polarity reversal: the "Reverse" LED switches on and the display shows the message 'Err7'' with a two-
second audible signal.
Analysis step in ''Charge'' : the display shows the scrolling message "ANALYSIS" alternated with the
measured voltage or current value; the LED corresponding to the function continues to flash until the
analysis is concluded. If the battery is in good condition the LED becomes steady on, otherwise the
display shows scrolling message "SULPHATED-BATTERY" and an intermittent audible signal is emitted.
Analysis step in ''Start'' : in the preliminary analysis function in "Start" the LED of this mode will flash
until a current absorption exceeding a minimum threshold is detected, after which the LED remains
steady on and the vehicle engine can be started.
Error Indications
The errors that may appear on the display are shown in table 1.
Table 1: Error Codes
DISPLAY
CAUSE
INDICATION
E01
Leads disconnected, leads short-circuited.
Battery completely short-circuited.
E02
Battery faulty or unrecoverable
No current accepted after 10 hours of recovery
E03
Internal overheating of battery charger
Battery charger overload
SOLUTION
Position the clamps correctly and start
charging the battery again; (see section
"How to use the battery charger").
The battery could be defective. Contact
your nearest battery service centre.
The battery could be defective. Contact
your nearest battery service centre.
Remove any objects that could be
covering the ventilation area of the battery
charger or move it to a cooler area. Wait
for the battery charger to start again
automatically.