Measurement using the
probe tip
Measurement using an
external sensor
Frequency filter
Operation
When conducting a measurement with the internal sensor, the noise is recorded with the
probe tip
.
The probe tip can be removed. If needed, you can unscrew it (right-hand thread) and
replace it with another probe, or you can install the supplied prolongation sticks between
the probe tip and the sensor.
Via the 5-pole socket
connected to the HL 50, e.g. the universal microphone PAM B-2. (There are more
sensors available from the optional accessories by SebaKMT.)
When connecting an external sensor, the HL 50 needs to be switched off. Pay attention
to the marks on the plug and the socket. The plug needs to lock tangibly.
When the HL 50 is switched on, it automatically recognises the external sensor. From
that moment, the values of the external sensor are indicated on the display.
Alternating between the internal and external sensor while operating the device is not
possible.
After removing the external sensor, the HL 50 does not automatically switch back to the
internal sensor. The device needs to be restarted for this purpose. Then the values of
the internal sensor are shown in the display again.
By clicking the button
frequency filter settings during the measurement:
Designation
Range
LO
0 ... 540 Hz
HI
540 ... 4000 Hz
ALL
0 ... 4000 Hz
at the bottom side of the device, an external sensor can be
the user can switch between the three following
High frequencies are cut;
(for operation as ground microphone)
Low frequencies are cut;
(for operation as test rod directly on the pipe or
valve etc.)
Broadband measurement without filter