Herunterladen Diese Seite drucken

SUEVIA 130P-H Montageanleitung Seite 4

Werbung

Fixation on walls
¾" - 1"
101.0525
½"
102.0352
Installation height
Hole Distance
102.0346
height adjustment
4
Fixation Model 13P-H
Fix the bowl with two appropriated screws on the wall. In case of desired fixation on
crossbared wall use a solid flat iron piece.
For taking off the cover the screw Ref. 102.0346 has to be unscrewed.
Installation Height
Recommended installation height from edge of bowl to straw or ground:
- in case of horses: 100 - 110 cm / 39,4 - 43,3"
- in case of cattle:
Hole Distance:
Attention!
Flush water line well before you connect the bowl!
Watter pressure
Maximal 5 bar / 72,5 psi water pressure!
Water Connection
We recommend as horizontal tube the use of a ¾" pipe. It is foreseen for installation of the
connecting pipe ½" the use of SUEVIA Boring Bracket Ref. 101.0525. Water connection
from right laterally. For connection from the top or bottom angular screwing ½"
Ref. 102.0352 is recommended. For connection from the left side the float valve can be
turned in the bowl.
Adjustment of Water Level
Water level in the bowl can be adjusted by changing the height of float valve.
Procedure:
Water level adjustment
Unscrew the screw Ref. 102.0346 and take off the valve cover.
Loose the brass screw Ref. 102.0614 and adjust the floater at the desired height.
Tighten the screw Ref. 102.0614,
put the valve cover back and tighten it well with the screw Ref. 102.0346.
Cleaning
Stop the water flow, open the drainage plug Ref.102.0258.
Let the water bleed. Close drainage plug, open the water flow.
Electric connection
All installation, maintenance and inspection works must be carried out only by an
authorised and qualified specialist. Local norms must be respected.
The assembly instruction of the respective electric devices are to be followed.
102.0258
Junction box
*
Not included in the scope of delivery of Mod. 130P-H!
70 - 80 cm / 27,6 - 31,5"
136 mm / 5,35"
Electrical connection
*
101.0389
IP44
*
Transformer
Junction box
*
Heating Cable
IP54
230 V
*
24 V
*
101.1410

Werbung

loading

Diese Anleitung auch für:

100.1305