1. Manual ignition
1. Open the valve of the gas cylinder.
2. Open the shut-off valve to the gas supply.
Manual ignition with Piezo igniter :
A
C
Manual ignition with battery igniter :
C
7. Release igniter button (C). Keep rotary switch (B) depressed for another 10-15
seconds, then release.
8. Check the flame indicator to see whether a flame is burning.
9. Repeat the entire process if the flame has gone out.
10. Use rotary switch (B) to regulate the temperature in the main refrigerator compartment.
2. Automatic ignition (RM 6291, RM 6401)
A
D
4. Keep rotary switch (B) depressed for another 10-15 seconds, then release.
5. Check the inspection glass (if existing) to see whether the flame is burning.
6. Adjust the temperature in the main refrigerator compartment using rotary switch (B).
Note:
If the flame goes out, the ignition system will repeat the ignition process automatically.
3. Set energy
selector switch
(A) to
5. Activate Piezo
ignition (C)
several times at
intervals 1-2
seconds.
5. Activate ignition
by pressing the
button (C) and
keep it depressed.
1. Set energy
selector switch (A)
to
3. The ignition process is activated automatically,
accompanied by a ticking sound; the indicator
lamp (D) will flash. Upon successful ignition, the
sound and the flashing will stop.
8
4. Press and hold
B
6. Check the inspection glass to
see whether there is a flame
(the inspection glass is insi-
de the refrigerator at the
bottom left).
6. Once the flame has been ignited
and is burning, the needle of the
galvanometer passes over into the
green section.
B
rotary switch (B)
2. Press and hold
rotary switch (B).