15 First-time usage
If you want to create your own configuration of the system
and do not need the example of installation pay attention
to the next steps. Please take notice of the important
terms concerning the alarm panel. You can now put the
alarm panel into operation.
1. Connect the 12V battery (7.0 Ah) to the
contacts of the alarm centre (note the colour
code:
red = +12V, black = 0V).
2. Using a screwdriver, short-circuit the two pins of
the kick-start jumper (see p. 14).
3. The green LED for the power supply (
begins to flash and the buzzers of the control
units can be activated. You can ignore the
display messages.
4. Enter the factory-set user code.
1234
This is:
. You can ignore the display
messages.
5. First close the housing of the burglar alarm
panel securely before switching on the 230V
voltage.
6. Switch on the 230V mains voltage to the burglar
alarm panel.
7. The green LED for the voltage (
constantly.
8. Now enter via the control unit:
factory-set programming code
The following shows on the display: Mult Syst?
9. Press Key 1 to create a partitioned system.
Press Key 0 to create a single system.
10. The display shows: PROGR. MODE
11. You are now in the program menu of the burglar
alarm panel and can start programming
)
) now lights
0
and then the
7890
.
31
UK