Herunterladen Diese Seite drucken

Schulte D969260 02 Montageanleitung Seite 20

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
FAQ
Problem
Reason
Hot and cold water
Hot and cold water interconverted
adjustment possible only
Minor water
Mistake in supply
Polluted sieve
amount/Ceasing water
Polluted catridge
amount
Polluted non-return valve
Polluted components connected in
series
Fitting flowing incessant Defect switch
Hot water is being pressed
Cross flow caused by not closing non
into the cold water pipe/or
retun valves
reversed
Twisting glider
Loose screwing
Height adjustment
Defect glider
impossible
Top wall mounting does
Fixing plate twisted by 180°
not hold
Temperature setting
Blocked slider in cartridge due to
impossible or tight
residue
Defect catridge
Mixed water temperature
Hot water temperature too low
can not be reached
Blocked slider in cartridge due to
residue
Water supply not according to
standard conditions
Cross flow caused by not closing non
retun valves
Flow heater/pumping station not
adequately dimensioned
Shifting tight/stuck
Diverter out of grease
Water flows out of both
Dirt in Diverter shank
outflows simultaneously
Defect switch
Switch not on stop
Dripping head shower
Shower head not horizontal/not
screwed tight
Dripping hand shower
Switch not on stop
Possible solution
Connecting the water supply in
reverse
Check hot and cold water supply
Clean filter at s-connection
Cleaning catridge
Cleaning non-return valve in the
entrance of cartridge and checking
the function
Cleaning nozzle/shower head
Exchanging the entire switch
Cleaning non-return valve in the
entrance of cartridge and checking
the function
Tightening the screwing
Exchanging the glider
Fit fixing plate correctly
Tilting the temperature
knob/descaling the cartridge
Exchanging the catridge
Increasign the hot water
temperature
Tilting the temperature
knob/descaling the cartridge
Adjusting the cartridge
Cleaning the non-return valve
Schaltstufen variieren, ggf.
Durchflussmenge anpassen
Cleaning and greasing switch /
exchanging
Clean diverter shank
Changing entire stop
Tilting switch on stop
adjust horizontal / screw tight
Tilting switch on stop
- 20 -
Notice
No reverse catridge existing
Radiator working? Water supply running?
Deinstall entire thermostat
16
see page
deinstall entire thermostat. Shank in RFV
has to run smoothly and adjust back to
initial position by the spring
Check the housing for possible dirt, clean if
18
necessary see page
deinstall entire thermostat. Shank in RFV
has to run smoothly and adjust back to
initial position by the spring
Tilt the knob regulary to prevent residue
16
see page
Assure that the hot water temperature is at
least 5°C higher than the desired mixed
water temperature
Tilt the knob regulary to prevent residue
17
see page
Check the housing for possible dirt, clean if
necessary
Check the housing for possible dirt, clean if
necessary see page 18

Werbung

loading