Fan dimensions [mm] are shown in the technical drawings on the packaging of the product.
The drawings present the structure of the fan and concern the following models:
Pic. A - WA, WAVE, BASIC, CLASSIC, RING, DISK, VECCO
Pic. B - other
Installation of the fan should begin with the removal of the masking front cover (1) and fan body cover (4)* -
both parts are tted by pressing them in and secured with screws.
Insert the power lead: depending on the model of the fan the lead should be guided through the opening (7) by
breaking in (6)*. Press the fan body (10) into the previously prepared opening in the wall or ceiling and secure
with screws through the mounting holes (11). Then, unscrew the screw or screws (2) and remove dome (3) to
gain access to the control plate (5).
Connect wires according to the connection diagram depending on the type of fan equipment.
Versions T, H and R: Set the time o delay value and sensor sensitivity (humidity or motion) using a screwdriver (8)* or
a tool with a sti , at non-conducting bar.
Place the dome (3) on the central part of the fan body and secure with screws (2). Put the cover (4)* and masking
cover on (1).
*parts not available in some models
Keeping the appliance in good condition - maintenance.
Work related to keeping the appliance in good technical condition should be entrusted only to trained
specialists.
• All maintenance work must comply with safety norms and health and safety regulations (PN-IEC 60364-3:2000).
• Before starting any work with the fan disconnect the power supply and secure from being reconnected!
• Air ducts of the fan need to be free from alien bodies - expelled items may pose danger!
• Do not perform maintenance tasks when the fan is operating!
• Pay attention to keep the work free from unnecessary vibrations!
• Intervals between technical maintenance depend on the cleanliness of the rotor!
• Thanks to using ball bearings with "lifespan lubrication" the motor does not require lubrication. After the period
of using grease (technical data) it is necessary to replace the bearings. In such case or in case of any other
damage (e.g. concerning winding or electronics) please contact the manufacturer.
Cleaning
.
In case of damaging the insulation there is shock hazard!
Before cleaning disconnect the power supply from the fan completely and secure it from
being reconnected!!
• Clean the front, mesh and visible cover parts with a damp cloth
• Do not use aggressive varnish dissolving agents!
• It is forbidden to use high pressure cleaner or water jets!
• During cleaning pay attention so that the liquid from the damp cloth does not reach the inside of the electronic
motor or junction box.
• After nishing cleaning the fan should be turned on and left working continuously for at least two hours - set to
from 80% to 100% of maximum revolutions so that the fan becomes dry.
The maintenance of the fan should be performed once every year. Mechanical and electrical connections should
be checked every three months. Additionally, if you hear or notice that the appliance is malfunctioning then it
should be checked. Keep the mesh of the fan cover clean.
1. The guarantee covers the e cient functioning of the fan for the period of 2 or 5 years – depending on the type
of model (information on the packaging) - counting from the date of purchase.
2. The guarantee without required purchase documents (receipt, invoice) is invalid.
EN
14
MAINTENANCE AND CLEANING
GUARANTEE TERMS AND CONDITIONS