The following table will help you locate and eliminate minor faults:
Fault
Control indicator
does not light up
No steam or spray
shot
Water drips out of the
ironing sole
28
Troubleshooting
Possible cause
Plug not inserted into
mains socket
No mains power
Control indicator defective
No water in the water tank
Temperature too low for
steam
Steam switched off
Water tank too full
Temperature too low
Steam flow too high
Steam shot button pressed
too often
Remedy
Insert plug
Check the mains socket or auto-
matic circuit breaker
Contact customer service.
Fill with water
Set temperature regulator to
"MAX" and allow the appliance to
heat up
Set the desired steam flow with
the steam flow regulator
Empty some water out of the
tank
Set temperature regulator to
"MAX" and allow the appliance to
heat up
Turn back steam flow regulator
Press steam shot button in
greater intervals