Removing the wine cooler section for thorough cleaning (for GL457 only)
1. Open the door (If your unit is with drawers, remove drawers and drawer guides).
2. Remove the screws on the left and right sides, using a hexagonal wrench.
3. Lift the wine cooler upward a bit then pull out.
Troubleshooting
A qualified technician must carry out repairs if required
Fault
The appliance is not
working
The appliance turns on,
but the temperature is
too high/low
The appliance is
unusually loud
CS102-CS103_GL186-GL188_GL456-GL457_ML_A5_v6_20230726.indb 5
CS102-CS103_GL186-GL188_GL456-GL457_ML_A5_v6_20230726.indb 5
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Condenser blocked with dust
Doors/ drawers are not shut
properly
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Ambient temperature is too high
Insufficient airflow to the fans
Appliance is overloaded
Factory default parameters
adjusted
The appliance is touching a
neighbouring object
The appliance has not been
installed in a level or stable position
Solution
Check unit plugged in correctly and
switched on
Replace Plug or lead
Replace the fuse
Check mains power supply
Clean Condenser
Check doors / drawers are shut and seals
are not damaged
Move the appliance to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Remove any blockages to the fans
Reduce the amount stored in the appliance
Consult a qualified Technician
Check installation position and change if
necessary
Check installation position and change if
necessary