Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - G-U BKS C-S P 100 Installationsanleitung

Zutrittskontroll-steuergerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation Instructions
Access Control Unit C-S P 100, C-S A 100
6

Electrical Connection

Connector
J1
J2
J3
J4
DIP-Switch (optional Wiegand-Output)
The default output format is TTL and Buzzer output.
But, you can configure the output to generate
output in Wiegand format and use it like a reader.
(The device can output data from card reading, but
cannot output data from keypad input.)
If you want to generate Wiegand instead of TTL
output format, follow the table below.
SW1 (1)
SW1 (2)
SW2 (1)
ON
OFF
ON
OFF
ON
OFF
Installation Instructions, Edition B dated 23/06/2010
Copyright © G-U GmbH, 2010. All rights reserved.
 
Signal
Voltage (+12 V)
Ground (GND)
Output door opener relay (COM)
Output door opener relay (NC)
Output door opener relay (NO)
Output alarm relay (COM)
Output alarm relay (NC)
Output alarm relay (NO)
Input door release button
Input door contact
AUX input 1
AUX input 2
Input Wiegand Data 0
Input Wiegand Data 1
TTL output
Buzzer output
AUX input 3
Reserve
Reserve
RS232-TX
RS232-RX
Ground (GND)
SW2 (2)
orange/white
OFF
TTL output
ON
Wiegand Data 0 output
Wire Colour
red
black
grey/red
blue/white
white/red
white
purple/white
purple
orange
yellow/red
green
green/white
pink
light blue
orange/white
brown/white
green/red
blue/red
yellow/white
black/white
red/white
black
brown/white
Buzzer output
Wiegand Data 1 output
Page 31 of 48