Track rail phase order
230V AC, 16A, 3.7 kVA
1-phase, 3-circuit
Track
Supply
L2
2
L
Max 16A
L
1
A
1
L
3
3
N
N
N-conductor I = max
16A
3-phase, 3-circuit
230/400V AC, 16A, 3x3.7 kVA
Track
Supply
Max 16A
L2
2
L1
B
1
L3
3
N
L1 + L2 + L3 = max 16A
230/400V AC, 16A, 11.1 kVA
3-phase, 3-circuit
Track
Supply
L2
Max 16A
L1
C
L3
N
N-conductor I = max
16A
L 1
L 2
L 1
DA (-)
N
L 3
N
GA 69 & GAC600 Dali - 230V, 6A
L 1
L 2
N
N
N
GAC600 Dali - 1A, 50V FELV
L 2
DA(+)
L 3
L 3
Max. 2,4Nm
DA
DA
Cleaning
OFF
CLEANING THE SPOTHEAD AFTER
THE LUMINAIRES IS COOLED DOWN
OR USE HEAT INSULATING GLOVES.
CLEANING ONLY WITH SOFT CLOTH!
Rotation maintenance
1
H2
3
T25
5
3/8
Head rotation
Max. 5,0Nm
H2
Max. 0,6Nm
2
4

Werbung

loading

Diese Anleitung auch für:

Stylid evo perfo st780s