LED INDICATION
The LED indicators on the control unit indicate the following events:
LED
Green on
Green blinking
No LED on
Level sensor 1 (yellow) not on
Level sensor 1 (yellow) on
Level sensor 1 (yellow) blinking
Sensor 2
Red LED not on
Red LED on
The BioFleece series have a micro-
processor controlled control unit
that can be connected to a PC by
means of a special cable. With
designated software it is possible
to read out the active status of the
filter and how often the motor has
been activated. The transmittance
of trigger times and updates are
also possible with this cable (only
available from official BioFleece
dealers).
Model
Pump capacity
Size (LxWxH)
Fleece roll width x length
Inlet
Outlet
Safety outlet
Waste outlet
Motor
Filter unit
Protection class
Cable length to 24V control unit
All electrical parts are CE and VDE approved.
Description
BioFleece is working
Delay time of 20 seconds
No power or error
Sensor not active
Sensor aktiv
Sensor error
No function (not operational
Motor not running
Motor running
Niveausensor 1
Red LED
BioFleece 300
5 – 8 m³/h
55 x 50 x 70 cm
300 mm / 100 m
50 mm
63 mm
50 mm
40/50 mm
24 volt
LDPE
IP54
5 meter
4
Note
20 seconds
Sensor is not in contact with water
Sensor is in contact with water
Sensor stays active
For any future applications
)
BioFleece 600
15 – 25 m³/h
85 x 50 x 70 cm
600 mm / 100 m
50 mm
90 mm
50 mm
40/50 mm
24 volt
LDPE
IP54
5 meter
Green LED
Sensor 2
Red button:
Manual control
motor
BioFleece 1000
30 – 40 m³/h
120 x 75 x 70 cm
1000 mm / 100m
2 x 63 mm
110 mm
75 mm
40/50 mm
24 volt
LDPE
IP54
5 meter
© SIBO BV versie 1.02 April 2009