SUPER COOL
5. LED-DISPLAY
The display shows the setting temperature in operation. By pressing the [TEMP+] or. [TEMP-] switch, the required target temperature is briefly displayed. On pressing
the [TIMER] switch, the number of hours is briefly shown until activation or deactivation. The display automatically shows the setting temperature. In the dehumidifica-
tion function, "DH" is shown in the display. Error messages are also shown in the display.
6. [SPEED]
Press this switch to set the ventilation speed to "LOW", "MID" (middle), "HI" (high) or "AUTO" (automatic). If "AUTO" is selected, the ventilator operates at temperature
differences larger than 9 degrees at top speed. If the temperature reduces to a difference smaller than 4 degrees, the ventilator switches to middle blower position. If the
temperature reduces further until the target temperature, the ventilator switches to the lowest blower position.
7. [TIMER]
Programmable time switch with start and residual time
Starting time: This function is used to switch on the unit automatically when the time entered has expired. Proceed as follows:
I) Press [TIMER] switch in Stand-by (this unit is connected but not in operation), to enter the required number of hours after which the unit is to start.
II) Select the required function (cooling, heating, dehumidification) and set the required temperature.
III) When the set number of hours has expired, the unit starts automatically.
If you press the [POWER] switch before the time has expired, the time programming is deleted. The unit switches on and can be operated in the required operating mode.
Residual time: This function is used to automatically deactivate the unit when the time entered has expired. Proceed as follows:
I) Press the [TIMER] switch during operation and enter the required number of hours after which the unit is to switch off.
II) After the flashing of the number of hours on the LED has stopped, you can select the required function (cooling, heating, dehumidification) and the required tempe-
rature.
III) When the set number of hours has expired, the unit switches on automatically.
If you press the [POWER] switch before the time has expired, the Timer programming is deleted and the unit switches off.
8. [SLEEP]
Using this key you can set the sleep function of the unit. The microprocessor integrated in the unit will raise the pre-set temperature by 2°C per hour up to a maximum of
4°C after 2 hours and maintain this temperature until the set time has expired. To change the temperature, press the switch [TEMP+] or [TEMP-]. With each press on the
switch, the temperature increases or decreases by 1°C.
9. [OSCILLATION]
Press the oscillation button to turn on the oscillation of the cold air outlet. Press again to stop. The shutters will return to the starting position when the device is turned
off.
Important
information
The device remembers the selected settings. After turning the device off
and back on using the button panel on the air conditioner, the device will
turn on with the last selected operating mode, set temperature, fan speed
and SWING function on or off. After disconnecting the device from the
power supply, the settings will be reset to factory settings.
When the air conditioner is turned on using the remote control, the
selected settings on the remote control will be turned on. The remote
control remembers only the operating mode, temperature and fan speed.
The SWING function will be activated automatically each time the device
is turned on using the remote control.
To start the air conditioner with a remote control without SWING
function, press the POWER button on the remote control and then press
the SWING button twice until the icon
flashes quickly.
NOTE - When connecting the pipe to the cold air outlet, it is recommended to turn off the SWING function,
because prolonged use of the air conditioner in this way, with the SWING function active may result in
damage to the SWING blade mechanism.
FRAL POLSKA Sp. z o.o. - www.fral.pl
Swing
-
automatic
oscillation
on the remote control display

REMOTE CONTROL

1. Power – switch on/switch off
2. FUN – select functions
3. Timer – time programming
4. Oscillation
5. Hi – high ventilation speed
6. MID – middle ventilation speed
7. LOW – low ventilation speed
8. SLEEP – sleep function (night mode)
9. TEMP – temperature control
Lights up - swing is working
Flashing slowly - swing is working
Flashing fast - swing not
18
FSC14.2 R290 PL/EN/DE/IT 26/01/2021 WER.3
FSC14.2 R290
2
3
5
1
9
8
4
7
6