4. OPERATION

The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Check
before the installation whether the electrical connections are earthed according to the statutory regulations
and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA. is
technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during pro-
longed operation. If the suction height is greater than 4m or the suction length is more than 9m, please make
the suction line 1 1/4 „(about 32mm) or 1 1/2" (about 38mm) instead of 25mm.
It is not recommended to perform even cable extensions or any other technical modifications. The lines to the pump must
be installed always steadily rising. A transfer of mechanical loads or vibrations from the pump or to the pump must be
eliminated through appropriate actions (use of rubber buffers, braided hoses, line fixation, etc.). If the suction height is
greater than 4m or the suction length is greater than 9m, please make the suction line in 1 1/4" (approx. 32mm) or 1 1/2"
(approx. 38mm) instead of 25mm. Do not reduce the suction line. Please install at the end of the suction line always a
check valve, if necessary with floating inlet (at use of rainwater this is mandatory). All pipe/hose connections to and from
the pump must be sealed (e.g. Teflon tape or sealing cord -
line „as one piece" without any interruption in order to prevent and avoid leaks. check valve and test water pipes for leaks
by means of a pressure test for at least 24 hours. Is dirt expected in the pump, an effective pre-filter should be installed
Fill pump and suction pipe/hose with water.
before the pump inlet.
Start the pump. If necessary, the pump and the suction line must be refilled until a normal continuous operation has been
established. If the pump is used outdoors, it must be protected against direct sunlight (risk of overheating) and rain (risk of
short circuit).
5. INSTALLATION SCHEME
Rainwater harvesting
Flexible hose
Floating ball
Non-return valve
10 cm
Pump operation in tank mode
fig.3
* Drinking water floating valve 3/4" male without float ball A373.
no
hemp!). We recommend that you implement the suction
30mA
Ground fault
circuit interrupter
Flexible hose
Steadily rising
suction pipe
Fixing line
fig.1
Floating ball
*
Floating valve
Please connect electrically pump with power supply.
System pressure increase
Low pressure water
in ow
The diameter of the
pipes to be connected
should correspond to the
pump connections.
Otherwise, additional noise,
negative pressure, etc. may
occur. The inlet pressure
should be at least 0.3 bar
lower than the start pressure
of the pump.
English 3
30mA
Ground fault
circuit interrupter
30mA
Ground fault
circuit interrupter
fig.2