Herunterladen Inhalt Inhalt Diese Seite drucken

NateoSante EOLIS Air Manager 600 Betriebs-Anleitung Seite 21

Vorschau ausblenden Andere Handbücher für EOLIS Air Manager 600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

WHEN MODE 2 IS ACTIVATED, IT IS VERY IMPORTANT TO FOLLOW THE SAFETY INSTRUCTIONS.
• Do not breathe the active oxygen directly
above the unit.
• Make sure NO ONE IS PRESENT in the room
during the treatment for 1 hour (men, women,
children, and also pets). Plants and fish may
remain.
• Close doors, windows, and turn off the
ventilation system.
• Active oxygen is made up of 3 molecules of oxygen (O
• The active oxygen generator recreates the phenomenon of lightning during a storm.
• It destroys VOCs, bad odours, bacteria, viruses, dust mites and spores.
• Active oxygen is better at killing certain micro-organisms than chlorine. Active oxygen created
electrically returns to its initial form of oxygen (O
• When this feature is inactive, your unit is emitting 0 ppm of active oxygen.
• When MODE 2 is activated:
1 - The unit emits active oxygen for 15 min at a low rate.
2 - For the following 45 min, the unit is no longer emitting active oxygen, and works at high speed to
adsorb the active oxygen in the air.
3 - After at least 1 hour, the unit begins operating normally with the preset settings.
You can return to the room.
Tones
The TONES are activated as soon as you press on a button, and as soon as active oxygen is
emitted. To activate the TONES, press the ON button. To deactivate them, press the OFF button.
High sensitivity
This mode is recommended for people who are very sensitive to air quality. The HIGH
SENSITIVITY mode should be activated in an indoor environment with little pollution when your
EOLIS Air Manager is in ACTIV MODE. The unit adapts its operation by taking the low level of
pollution into account, and can therefore detect smaller peaks in pollution. To activate the HIGH
SENSITIVITY mode, press the ON button. To deactivate it, press the OFF button.
Reset
To RESET the settings on your unit, press the ON button. All of the custom and saved data will
be erased.
Demo
DEMO mode is a general presentation tool for the EOLIS Air Manager (used mainly in retail outlets
where this model is sold). To activate DEMO mode, press the ON button. To exit this mode, press
on the cross in the top left corner of your screen. To hide this mode, hold down the OFF button.
Version
Get technical information about your EOLIS Air Manager (model and software). This information
may be requested when you contact your dealer.
Boootloader
Function accessible only by your dealer
Replacing filter block
When should I replace the pre-filter?
The lifespan of the pre-filter depends on the environment in which it is used. The pre-filter should be
replaced regularly (every 3 to 4 months on average) in order to limit filter clogging. It is essential that you
monitor the pre-filter regularly to check its status.
21 - EOLIS Air Manager 600 600S 1200 1200S
21 - EOLIS Air Manager 600 600S 1200 1200S
• As soon as you press START, a countdown
appears telling you that you have 30 sec to leave
the room:
TRAITEMENT A L'OXYGENE ACTIF PENDANT 1H
EVACUEZ LA PIÈCE
DÉBUT DANS 30 S
As you leave, close the door behind you.
).
3
) in a few hours.
2
EN
EN

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für NateoSante EOLIS Air Manager 600

Inhaltsverzeichnis