BAE PS-XA-1W-24-150-6_ _-I / BAE PS-XA-3Y-24-250-6_ _-I
Power supply units

2. IO-Link Interface

The IO-Link interface used in this power supply is compliant to IO-Link protocol V1.1 and can be connected to any
IO-Link masters compliant to V1.1 of the IO-Link protocol. This allows a transparent data flow to the sensors and
actuators and therefore more transparent and easier way to monitor the current status of the power supply.
In case of no or defective connectivity of the IO-Link, the power supply can also be operated on smoothly. Due to
a built-in EEPROM, previously inputted data will be drawn from its storage.
To operate the IO-Link interface it is required to install/upload the IODD-File (IO-Link Device Description) into the
connected IO-Link master. The most recent IODD file can be found be found at www.balluff.com on the product
page. The device can also be accessed via IO-Link, if the power supply is not connected to AC-mains and in a
switched off mode.
IO-Link Version
IO-Link master Version
Baud-Rate
Cycle Time
SIO-Mode
Process Data Length
The power supply provides three categories of data via IO-Link. They are divided between read only or read- and
customizable data.
www.balluff.com
V1.1
To get full performance, it is recommended to use IO-Link
V1.1
COM3 (230.4 kBaud)
Cycle time refers to the reloading speed of certain process
2ms
data
yes
Class B
23 bytes