This product allows you to choose the operating mode (extraction or filtering) according
to installation.
This model should only be set in the filtering version.
On first start-up for a few seconds the display shows which mode is active.
Filtering: the display indicates: FC1
Extraction: the display indicates: FC0
During this phase, you can change the mode by pressing key: 5
To confirm the selection, press the key: 6
To reference the operating mode selection, disable and re-enable voltage to the appliance.
Key:6 on/off motor: pressing the key starts both the motors at first speed or if already on it causes
switch off.
This device is equipped with a dual motor, on the right and left, with independent and/or
synchronised operation.
To select each motor, use key 3 (for the left motor), use the key: 8 (for the right motor).
To increase and reduce the speed of the motor, use the key: 4 (to decrease), use the key: 7 (to
increase)
Key: 1 synchronises the two motors aligning the speed between the two motors at the highest
speed
use the key: 4 (to decrease), use the key: 7 (to increase).
To switch off a single motor use the key: 3 (left motor) use the key: 8 (right motor).
Clock adjustment: to adjust the time, simultaneously press the key: 4 and the key: 7 with the
motors off and lights off, using keys 4 and 7 set the correct time, to confirm simultaneously press
the key: 4 and the key: 7.
Timer: to enable this function with the motor on, simultaneously press the keys 5 and 7, the timer
indicates 10 minutes to increase or decrease the time using the keys 7 and 4 .
Filter management: on pressing the key: 5 on the display the wear status is displayed of the filters
expressed as a percentage: FC (carbon filters),on subsequent pressing the key: 5 the display shows
the wear status of the grease filters FG (grease filters).
Saturated filters: if the key: 5 flashes with the hood on, or remains fixed in standby, the display
on switching on the motor will display the status of the filters: you must wash the grease filters or
replace the carbon filters.
Reset filters: following maintenance or replacement of the various filters to reset the alarm press
the key: 5, press the key for a long time: 5 the timer will reset and a beep confirms the operation
carried out.
2