8. Mounting of the control panel

To install the control panel, use the template provided. Place the template on a plane or panel, perpendicular to
the induction cooker, centering it to the cooker whenever possible.
The control panel cut out should measure 360mm long x 130mm wide. Place the control panel into cut-out hole.
Using the metal bracket provided, secure the control panel into place. The control panel is meant to adjust 10mm
to 20mm thickness, depending on the surface it is being mounted to. Connect the control box cable to the
induction cooker.

9. How to clean

1. Disconnect plug and wait until the unit is cooled down completely. Clean after using every time.
2. If the pots/pans are used without being cleaned, discoloration or cooked on stains may be caused.
3. Do not use benzine, thinner, scrubbing brush or polishing powder to clean the induction cooker.
4. Wipe using dish washing agent and damp cloth.
5. Use vacuum cleaner to suck up dirt from the air intake and exhaust vent.
6. Never run water over the unit (Water gets inside may cause malfunction).

10. Trouble shooting

Error Codes
Potential Reasons
E1
Induction cooker overheat
E2
Stove-top overheat
Voltage under-loaded/
E3
over-loaded
Solution
Clear all obstacles that block the vent under the bottom of
the induction cooker, then place the cooker in an open area
and try again after the appliance cools down.
Make sure water is inside the pan.
Make sure the voltage and frequency comply with the
rating label shown on the product.
www.combisteel.com