Herunterladen Diese Seite drucken

DeFelsko PosiTest DT Bedienungsanleitung Seite 5

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Recording the Results:
Remove the tape from the Transparent Display Board and place it on
the provided Dust Test Kit Report Form. Under "Dust Quantity
Rating" record the number of the pictorial reference which most closely
corresponds to each Test Sample AND under "Dust Size Class" record
the dust particle size using the Description of Dust Particles shown on
the Dust Test Comparator.
Perform a sufficient number of tests to adequately characterize the
surface under test. For every surface type, perform at least 3 separate
tests. If the Dust Quantity Rating results differ by more than one,
perform at least 2 additional tests and average the results of all tests.
NOTE:
Tape and adhesive residue should be removed before the ap-
plication of coatings.
Consumable Accessories
Dust Test Comparator Display Board, Report
Forms, Transparent Display Board
DeFelsko Adhesive Tape
Item Code
DTREPORT
CHDTISOTAPE