Operation

Users can select one of 4 ventilation settings us-
ing the button on the main control unit: absent,
present, maximum or "Auto CO
lected is indicated by a blue LED. The ventilation
is automatically controlled in the "Auto CO
ting based on the CO
the main control unit is used, this relates exclu-
sively to the CO
levels in the living room. If the
2
upgrade sensors are also used, then this highest
CO
concentration is normative for the ventilation
2
volume. The upgrade sensor does not function as
a control unit and is only intended to monitor CO
levels in a living area. There are 3 LED indica-
tors on the sensors which display the CO
Green (<1200ppm);
Orange (1200 – 1500ppm);
Red (>1500ppm).
Residents are advised to open a door or window
if the red LED lights up. Furthermore all gaps un-
der doors - which are essential for effective ven-
tilation - as well as the position of window grat-
ings (if fitted) must be checked.
Malfunction
The following malfunctions can occur:
The green, orange and red LEDs flash. The
3-position switch on the main control unit
still works. The CO
seriously contaminated. Clean the CO
sor or replace it;
The red LED flashes, while the green or
orange LED is constantly illuminated. The
sensor cannot establish a connection with
the ventilation unit. Check the distance and
for the presence of any large metal obsta-
cles between sensor and ventilation unit.
14 - EN
". The setting se-
2
2
concentration. When only
2
levels:
2
sensor is defective or
2
2
Maintenance
The CO
2
out the entire lifespan. The operation can be in-
terrupted by contamination of the air channels.
Remove the dust from the casing and from the
" set-
air channels where required.

Specifications

CO
RF main control unit and
2
CO
RF upgrade sensor
2
Power supply: 230V±10%, single-phase,
50Hz;
2
Minimum ambient temperature: -10°C;
Maximum ambient temperature: +40°C;
Humidity (continued): 85% (electronics),
non-condensing;
Functional measurement range 400ppm -
2000ppm;
Sensor malfunction if measurement value is
<300ppm or >10000ppm;
Target value 1050ppm;
Output signal 0%RF-100%RF, proportional;
integrating subject to target value deviation;
Unit consumption: typically < 1W;
Degree of pollution: 2;
Peak voltage: 4 kV;
Protection class: II in compliance with
sen-
EN60730-1;
IP classification: IP30 in compliance with
EN60529-1;
Type of regulator: RS type 1.
sensors are maintenance-free through-