4
Important Safety Warnings
Place the UPS indoors in an area that has adequate
airflow and no excessive dust. Do NOT allow the
UPS to be exposed to moisture, rain, excessive
heat or direct sunlight.
The use of the UPS is NOT recommended in
life support applications where failure of this
equipment can reasonably be expected or when
its safety or effectiveness could be affected
significally.
Do not plug the UPS input into its own output.
Please always disconnect the input power cord
from the wall outlet before replacing the battery.
Do NOT dispose of the battery in a fire. The
battery may explode.
Do NOT open or damage the battery. It contains
an electrolyte that is toxic and harmful to the skin
and eyes.
Proper disposal of the battery is required. Please
follow your local laws/regulations regarding
battery disposals.
Use tools with insulated handles to replace the
battery to avoid personal injury. Due to energy
hazard, please remove wrist watches and hand
jewerly when replacing the battery.
06
5
Troubleshooting
Problem
Possible Cause
Batteries are not
The UPS does not
fully charged.
perform expected
Battery is slightly
runtime
worn out.
The on/off switch
is designed to
prevent damage by
rapidly turning it
off and on.
The unit is not
The UPS will not
connected to an
turn on.
AC outlet.
The battery is
worn out.
Mechanical
problem.
Circuit breaker
is tripped due to
overload
Outlets do not
provide power to
equipment
Batteries are
discharged
Unit has been
damaged by a
surge or spike.
Alarm sounding
Utility Failure
Solutions
Recharge the battery by
leaving the UPS plugged in.
Contact Technical Support.
Turn the UPS off. Wait 10
seconds and then turn the
UPS on.
The unit must be
connected to a 230Vac
50/60Hz outlet.
Contact Technical Support.
Contact Technical Support.
Turn the UPS off and
unplug at least one piece
connected equipment.
Unplug the power cord
of the UPS then press the
circuit breaker knob.
Allow the unit to recharge
for at least 8 hours.
Contact Technical Support.
The audible alarm can be
turned OFF or ON by quickly
pressing the POWER button
twice. The default setting
for the alarm is ON.
Note: The UPS is making 2 short
beeps when the alarm is turned
OFF and 1 short beep when is
turned back ON.
07